Main
Code
Sub
Code
Error
Logger
Alarm
Status
Alarm
Indica-
tor
Blinking
Cycle
Description
B00
○
○
1 sec.
The temperature sensor of optical block assembly Ch-1A detec-
ted an abnormality.
C00
○
○
1 sec.
The temperature sensor of optical block assembly Ch-1B detec-
ted an abnormality.
3D
901
○
○
0.25 sec.
The 5V-SAG detection function was activated disabling the sys-
tem to start.
3E
500
○
○
1 sec.
The drive is not placed in the correct orientation.
*1
Place the drive
at the correct orientation.
*1
501
○
○
0.25 sec.
The drive is not placed in the correct orientation.
*1
Place the drive
at the correct orientation and then turn off and on the power.
*1
2-1-4.
Error 5X
When a read data error is detected, one of the following error codes is displayed.
Main
Code
Sub
Code
Error
Logger
Alarm
Status
Alarm
Indica-
tor
Blinking
Cycle
Description
50
010
○
○
0.25 sec.
BCA area data cannot be read.
011
○
○
0.25 sec.
BCA area data is invalid.
51
020
○
○
0.25 sec.
PIC area data cannot be read.
021
○
○
0.25 sec.
PIC area data is invalid.
500
○
○
0.25 sec.
An unspecified disc was inserted.
*2
52
00B
○
○
0.25 sec.
No address can be read from the disc in optical block assembly
Ch-0A.
08B
○
○
0.25 sec.
No address can be read from the disc in optical block assembly
Ch-0B.
10B
○
○
0.25 sec.
No address can be read from the disc in optical block assembly
Ch-1A.
18B
○
○
0.25 sec.
No address can be read from the disc in optical block assembly
Ch-1B.
53
500
–
○
0.25 sec.
Recording to disc was attempted with no available spare area.
54
000
–
○
1 sec.
Unsupported REC mode was detected in the recording disc.
001
–
○
1 sec.
Unsupported PAC is used in the recording disc.
002
–
○
1 sec.
Unsupported spare area is used in the recording disc.
003
–
○
1 sec.
Unsupported DFL entry was detected in the recording disc.
004
○
○
1 sec.
A data error was detected when the cartridge memory data was
read.
005
○
○
1 sec.
A device error was detected when data was written to the car-
tridge memory.
006
○
○
1 sec.
An unsupported data format was detected in the cartridge mem-
ory read data.
007
○
○
1 sec.
An unsupported data format was detected when data was written
to the cartridge memory.
(Including data CRC error)
Continued
*1:
For the correct orientation, refer to the Operation Manual or the Installation Manual of each model.
*2:
For discs that can be read and written in this unit, refer to the Operation Manual.
ODS-D77U/ODS-D77F
2-6
Summary of Contents for ODS-D77F
Page 4: ......
Page 7: ...8 Diagrams Block Diagrams 8 1 Frame Wiring 8 5 ODS D77U ODS D77F 3 ...
Page 8: ......
Page 10: ......
Page 42: ......
Page 53: ...Section 3 Maintenance Mode This section will be described soon ODS D77U ODS D77F 3 1 ...
Page 54: ......
Page 80: ......
Page 82: ......
Page 102: ......
Page 103: ......