Main
Code
Sub
Code
Error
Logger
Alarm
Status
Alarm
Indica-
tor
Blinking
Cycle
Description
008
○
○
0.25 sec.
A comparison error between the disc BCA code in the cartridge
memory and the actual media BCA code was detected.
009
○
○
0.25 sec.
A comparison error between the media type in the cartridge
memory and the actual media type was detected.
200
–
○
1 sec.
A TDMA area error was detected during write-back to the re-
cording disc or formatting.
201
–
○
1 sec.
A disc error was detected during finalizing of the recording disc.
2-1-5.
Error 6X
When a failure is detected relating to a startup operation or relating to an adjustment before writing, one of the following
error codes is displayed.
Main
Code
Sub
Code
Error
Logger
Alarm
Status
Alarm
Indica-
tor
Blinking
Cycle
Description
61
000
○
○
1 sec.
Depletion of OPC area in the disc was detected.
6F
E00
○
○
1 sec.
Startup adjustment or OPC cannot be finished in optical block
assembly Ch-0A.
E03
○
○
0.25 sec.
Adjustment failed in starting optical block assembly Ch-0A.
E80
○
○
1 sec.
Startup adjustment or OPC cannot be finished in optical block
assembly Ch-0B.
E83
○
○
0.25 sec.
Adjustment failed in starting optical block assembly Ch-0B.
F00
○
○
1 sec.
Startup adjustment or OPC cannot be finished in optical block
assembly Ch-1A.
F03
○
○
0.25 sec.
Adjustment failed in starting optical block assembly Ch-1A.
F80
○
○
1 sec.
Startup adjustment or OPC cannot be finished in optical block
assembly Ch-1B.
F83
○
○
0.25 sec.
Adjustment failed in starting optical block assembly Ch-1B.
2-1-6.
Error 91
When an operation error of the CPU or DSP is detected, one of the following error codes is displayed.
Main
Code
Sub
Code
Error
Logger
Alarm
Status
Alarm
Indica-
tor
Blinking
Cycle
Description
91
515
○
○
0.25 sec.
Communication with the SATA host is disabled.
557
○
○
0.25 sec.
A firmware alarm or startup of the recovery firmware was de-
tected.
565
○
○
0.25 sec.
Communication between SYCPU (IC720: BD-44 board) and
FPGA (IC700: BD-44 board) cannot be established during start-
up.
567
○
○
0.25 sec.
Failure in SYCPU (IC720: BD-44 board) firmware upgrade was
detected during startup.
Continued
ODS-D77U/ODS-D77F
2-7
Summary of Contents for ODS-D77F
Page 4: ......
Page 7: ...8 Diagrams Block Diagrams 8 1 Frame Wiring 8 5 ODS D77U ODS D77F 3 ...
Page 8: ......
Page 10: ......
Page 42: ......
Page 53: ...Section 3 Maintenance Mode This section will be described soon ODS D77U ODS D77F 3 1 ...
Page 54: ......
Page 80: ......
Page 82: ......
Page 102: ......
Page 103: ......