4-8
PCS-1500/1500P
Symptom: Cannot connect to the circuit (V.35).
4-1. Check Items Before Starting Self-diagnostics
YES
YES
YES
NO
NO
NO
NO
NO
YES
YES
SS-09
0-0
Contents of the dial
list setup and system
setup are correct?
Cable connections,
TA setup and NCU setup
are correct?
When the loop
back number of Telecommunication
Company is dialed up, the
line is connected?
The loop back
number of Telecommunication
Company can be called by
manual dialing?
The system operates
normally when the IF-745
board is replaced
Replace the IF-745 board
Set them correctly
Connect and set them correctly
Remote station is defective, or
their setup is incorrect
Line is defective, or TA or
NCU is defective