4-24
PCS-1500/1500P
m
.
To perform the self-diagnostics, be sure to connect a camera to the system before starting the diagnos-
tics.
.
When #diag
[|]
auto
↓
is completed, confirm that FAIL has not appeared in all messages during the
course of diagnostics. If FAIL has occurred, go to and perform the section “When self-diagnostics
results in FAIL” of the block in which FAIL has occurred.
.
If collapsed messages displayed, setting of the communication conditions may be wrong.
4-2. Self-diagnostics Function
0-0
YES
YES
YES
YES
YES
#install
[|]
7a0000
↓
#diag
[|]
setVCPDRAMSize
[|]
4
↓
#diag
[|]
auto
↓
NO
NO
MEMORY TEST
PASSED?
ALL TEST PASSED?
NO
NO
YES
NO
NO
P-01
C-01
The
POWER LED indicator
turns on when the POWER
switch of processor
is pressed?
Connect a terminal to the DIAG
port and start up the DIAG mode
The DIAG startup
message appears?
Diagnostics on each block
Replace IC101 and IC102
When self-diagnostics
results in FAIL
Settings such
as cable and connector
connection and communication
condition are
correct?
The message
that is being displayed is
the log of the application
software?
IC200, IC100 and their peripheral
Set them correctly again
Summary of Contents for PCS-1500