PCS-1500/1500P
4-2. Self-diagnostics Function
A-8
IC300 [35]
=
3.3 V?
YES
YES
NO (PutByte Timeout)
V-2
NO
X300 = 40 MHz?
IC300
IC110
YES
YES
NO
NO
IC300 [126] = 27 MHz?
YES
YES
NO
NO
“Downloading is
OK” when judged from the
result of the
diagnostics?
“DRAM Test
PASSED” when judged
from the result of the
diagnostics?
The input video
signal (NTSC/PAL) including
the camera signal has
no error?
IC303, IC304, IC305, IC306
or their peripheral
Check the input signal
IC354, IC352 or their peripheral
Replace X300
m
.
When an error occurs during the DRAM test of VCP, the DRAM may be defective, or the clock (27
MHz, V-Sync) of the video system may be not input correctly.
.
When the application does not work even though the system has PASSED self-diagnostics, a trouble
may be existing inside the VCP. Replace the VCP (IC300).