5-1
PCS-1500/1500P
Section 5
On Screen Messages
5-1. On Screen Messages
The following messages appear on the TV monitor when using the Compact Processor and gives instruc-
tions on dealing with them.
Message
Remedy
INCORRECT DIALING SETUP
Make sure the selected entry is correctly registered.
CANNOT COMPLETE CONNECTION
(The following code and message appear.)
0
Unknown network error
Please try again later.
1
Number does not exist
Please check the number and try again.
2, 3, 6 Network congestion
Please try again later.
16
Normal disconnection
(Normal disconnect)
17
Line is busy
Please try again later.
18
System not responding
Please check if remote system is connected.
19
No answer from user
Please check if other party is present.
21
Call rejected by network
Please check access restrictions remote site.
22
Called party number changed
Please check the number and try again.
26
Non-selected user clearing
Please try again later.
27
Remote system out of order
Please contact remote party.
28
Invalid number entered
Please check the number and try again.
31, 34, 41 – 44, 47 Network not available
Please try again later.
50
Not Subscribed
Please check the remote party’s facility subscription.
57, 58 Bearer capability not authorized
Check if the line rate is set correctly.
70
Line Rate Error
Please check if the line rate is set to correctly.
88
Incompatible equipment on remote site
Please check if remote party has compatible system.
91, 95 – 102, 111 Local system out of order
Restart system and try again.
128 H.221 Negotiation timeout
Power off and power on.
131 Hardware failure
Check the line interface boards.
132 SPID registration incompatible
Please register SPID.
144 Bonding Negotiation timeout
Power off and power on.
145 Bonding Negotiation failed
Power off and power on.
FAR END INACTIVE
The remote party operates the menu.
PLEASE CLOSE THIS MENU
Close the menu.
CANNOT ESTABLISH
Check to see if your partner’s telephone number is the correct
ALL CONNECTIONS
one.
CONFIGURATION ERROR
Wait for a while and then try dialing again.
Command is rejected by MCU
The function is not supported for MCU if the same operation
displays this message again.
CORRUPTIVE DATA STREAM.
A signal error occurred. The line connections are compelled to be
TERMINATE THE CONNECTION
disconnected.
PLEASE INPUT TITLE
Input an index title.