2-8
PCS-1500/1500P
2-5-4. RX-47 Board
Replacement Part
Part name :
RX-47 board
Part number : A-8322-884-A
Replacement Procedure
1.
Remove the upper cabinet. (Refer to Section “2-4.
Removing the Cabinets”.)
2.
Remove the screws fixing the RX-47 board that is
connected to the MA-97 board.
3.
Remove the shield B.
4.
Remove the RX-47 board that is connected to the
CN790 of the MA-97 board.
2-5. Replacing the Main Parts
5.
Attach the new RX-47 board by reversing the disas-
sembling procedure of steps 1 to 3.
n
Standard tightening torque : 80
x
10
_
2
N
.
m {8 kgf
.
cm}
PSW3
x
6
CN790
RX-47 board
MA-97 board
Shield B