172
Specifications
App
end
ix
Error messages
Error codes appear in the time data display when an error
(usually a hardware problem) occurs. In addition, both
error messages and error codes appear in the monitor video
section and on the video monitor connected to the unit.
When an error message appears, follow the instructions in
the error message to resolve the problem.
To eject discs with the unit powered
off
As an emergency measure, disc cartridges can be removed
with the unit powered off. This operation should always be
done by a trained service technician.
Specifications
General
External dimensions (w/h/d, excluding projections)
210×132×396 mm (8
3
/
8
×5
1
/
4
×15
5
/
8
inches)
Mass
6.5 kg (14 lb. 5 oz.)
Power requirements
100 V to 240 V AC, 50/60 Hz
12 V DC
Power consumption
AC operation: 80 W
DC operation: 65 W
(Power saving mode: 55 W)
Peak inrush current
(1) Power ON, current probe method:
45 A (240 V), 18 A (100 V)
(2) Hot switching inrush current,
measured in accordance with
European standard EN55103-1: 11 A
(230 V)
Operating temperature
5ºC to 40ºC (41ºF to 104ºF)
Storage temperature
–20ºC to +60ºC (–4ºF to +140ºF)
Operating relative humidity
25 to 90%
System
Recording/playback format
Video
MPEG HD 422: 50 Mbps
Proxy video
MPEG-4
E r r o r 5 0 - 0 1 0
ERROR
AN ERROR HAS BEEN
DETECTED. INFORM SERVICE
OF FOLLOWING CODE:
50-010
PRESS EJECT KEY
TO EJECT DISC.
Error code
Error code in time data display area
Error code
Example error in video monitor screen
in mm (inches)
210 (8
3
/
8
)
132 (5
1
/
4
)
396 (15
5
/
8
)