86
System Menu
Cha
p
te
r 6
Me
nu
s
TIME CODE [Time Code]: Settings related to the timecode
generator
Description
TCG REGEN [> TCG regen]:
Select the signals to generate
when the timecode generator is set to regenerate mode
(TC MODE on page P1 of the function menu is set to
“REGEN”).
*
TC & UB [>> TC & UB]:
Regenerate both timecode signals
and user bits signals.
TC [>> TC] :
Regenerate timecode signals only.
UB [>> UB]:
Regenerate user bits signals only.
UB BINARY GP. [> Binary Gp.]:
Settings related to the user
bits binary group flag.
Note
When TC MODE on page P1 of the function menu is set to
“REGEN”, the user bits binary flag setting of external timecode
is followed.
*
000:NOT SPECIFIED [>> 000]:
Character set not specified
001:ISO CHARACTER [>> 001]:
8-bit characters conforming
to ISO 646 and ISO 2022
010:UNASSIGNED-1 [>>010]:
Undefined
011:UNASSIGNED-2 [>> 011]:
Undefined
100:UNASSIGNED-3 [>> 100]:
Undefined
101:PAGE/LINE [>> 101]:
Multiplex
110:UNASSIGNED-4 [>> 110]:
Undefined
111:UNASSIGNED-5 [>> 111]:
Undefined
VITC POS SEL-1 [> VITC pos-1]:
Select a line to insert the
VITC in.
Note
You can insert the VITC signal in two places. To insert it in two
places, set both this item and VITC POS SEL-2.
When the system frequency is 60i, 23.98P or 30P
20LINE [>> 20 line] to 12LINE [>> 12 line]:
Select any line
from 12 to 20.
Factory default setting:
*
16 LINE [>> 16 line]
Note
When the system frequency is 60i, 23.98P, or 30P, the VBID
(Video Blanking ID) receives priority over a selection of
“20LINE”.
When the system frequency is 50i or 25P
22LINE [>> 22 line] to 9LINE [>> 9 line]:
Select any line from
9 to 22.
Factory default setting:
*
19 LINE [>> 19 line] (line 19)
VITC POS SEL-2 [> VITC pos-2]:
Select a line to insert the
VITC in.
Note
You can insert the VITC signal in two places. To insert it in two
places, set both this item and VITC POS SEL-1.
When the system frequency is 60i, 23.98P or 30P
20LINE [>> 20 line] to 12LINE [>> 12 line]:
Select any line
from 12 to 20.
Factory default setting:
*
18 LINE [>> 18 line]
Note
When the system frequency is 60i, 23.98P, or 30P, the VBID
(Video Blanking ID) receives priority over a selection of
“20LINE”.
When the system frequency is 50i or 25P
22LINE [>> 22 line] to 9LINE [>> 9 line]:
Select any line from
9 to 22.
Factory default setting:
*
21 LINE [>> 21 line] (line 21)
PD PRESET [> PD preset]:
Select the timecode to preset.
The A-frames of pulldown sequences are preset.
24F TC [>> 24F TC]:
Preset 24-frame timecode.
30F TC [>> 30F TC]:
Preset 30-frame timecode.
DISC PROTECTION [Disc protct]: Settings related to disc
protection
Description
STILL TIMER [>> STL timer]:
Specify the length of time the
unit can be in still image mode before switching to disc
protection mode.
0.5SEC [>>> 0.5 sec] to 30MIN [>>> 30 min]:
Select time
from 16 settings ranging from 0.5 second to 30 minutes.
Factory default setting:
*
8MIN [>>> 8 min] (8 minutes)
VIDEO CONTROL [Video]: Settings related to video
control
Description
INT VIDEO SG [> Video SG]:
Select the test signal to be
output from the internal test signal generator.
*
100% COLOR BARS [>> 100% bars]:
100% color bar signal
RAMP(Y/C) [>> Ramp]:
Bias signal
GRAY [>> Gray]:
Grayscale signal
BLACK BURST [>> BB]:
Black burst signal