6(E)
Power requirements
100 to 240 V AC, 50/60 Hz
Current drain
100 V AC: 1 A
240 V AC: 0.5 A
Peak inrush current
(1) Power ON, current probe
method: 33 A (240 V), 10 A
(100 V)
(2) Hot switching inrush current,
measured in accordance with
European standard
EN55103-1: 8 A (230 V)
Power supply capacity
+12 V DC: max. 4.4 A
Operating temperature
+5°C to +40°C
(+41°F to +104°F)
Performance guaranteed temperature
+10°C to +35°C
(+50°F to +95°F)
Storage temperature
–20°C to +60°C
(–4°F to +140°F)
Operating humidity
10% to 90%
(no condensation)
Dimensions
440
×
43.6
×
550 mm (w/h/d)
(17
3
/
8
×
1
3
/
4
×
21
3
/
4
inches)
Mass
Approx. 8.5 kg (18 lb 12 oz)
(not including the optional
boards)
Inputs
Remote
S-BUS remote connector:
BNC type (1)
Sync input
HD tri-level sync/black burst:
BNC type, 2 pairs (with loop-
through outputs)
Status output
STATUS OUT:
Mini D-sub 15-pin, female (1)
Supplied accessories Operation Manual (1)
Installation Manual (1)
Design and specifications are subject to change
without notice.