1-3-6.
System Control
DPR-343 Board
The 32-bit RISC CPU (ARM) with ARM core is built-in as the system controller (IC2101).
It has the peripheral interface functions of SDRAM, USB, SCI, and I
2
C. It operates on a 27 MHz clock (X2000).
FLASH ROM (IC2007), SDRAM (IC2006), and EEPROM (IC2201) are mounted as the peripheral ICs.
It performs the system control through serial communication with IC702 (DCP-56 board) of the camera block system,
IC900 (DCP-56 board) of the video signal system, and IC1000 of the media recording/playback system.
Main functions of the system controller and peripherals
Reading operation switch information
Reading the switch information and the LED control are performed by I
2
C bus communication with each sub-
microprocessor.
• Handle switch: IC202 on the KSW-62 board
• Inside panel switch: IC200 on the SWC-54 board
• Power supply switch: IC202 on the RE-298 board
Clock IC (RTC) control
The AU-342 board contains a clock IC (IC700).
The clock IC (IC700) backed up by a lithium coin battery monitors the battery voltage via IC200 on the SWC-54 board.
The clock IC (IC700) and the system controller set and read the current clock time through serial communication.
Infrared remote control demodulation
The RM-237 board has an IC (IC100) for REAR infrared remote control signal demodulation, and it receives the
command codes via IC200 on the SWC-54 board. The KSW-61 board has an IC (IC100) for FRONT infrared remote
control signal demodulation, and it receives the command codes via IC202 on the KSW-62 board.
Info-Battery communication
The Info-Battery of SM bus specifications is supported.
The serial terminal of the battery connector is connected to IC202 on the RE-298 board. This IC202 read the battery
authentication, battery type, remaining power, and other information and send them to the system controller via I
2
C bus
communication.
Power supply voltage detection
The power supply voltage at the DC IN connector is measured by the A/D port on IC202 on the RE-298 board, and it
is posted to the system controller as the input voltage value.
Power system control
IC202 on the RE-298 board checks that the power switch on the unit is turned ON, and turns on the system controller
of IC2101 (DPR-343 board). After that, it controls the power for each circuit block according to the system controller.
The system controller controls the respective power supply systems in the RE-299 and RE-300 boards according to the
operation mode of the device, via the power supply microcomputer (IC202) on the RE-298 board.
PMW-200/PMW-EX280
1-9
Summary of Contents for PMW-200
Page 1: ...SOLID STATE MEMORY CAMCORDER PMW 200 PMW EX280 SERVICE MANUAL 1st Edition Revised 1 ...
Page 4: ......
Page 8: ......
Page 10: ......
Page 30: ......
Page 38: ...3 Install the removed parts by reversing steps of removal PMW 200 PMW EX280 2 8 ...
Page 82: ......
Page 96: ......
Page 128: ......
Page 130: ......
Page 132: ......
Page 133: ......