2-13. Handle
2-13-1. Handle Assembly
Preparation
1.
Remove the battery lid. (Refer to
2.
Remove the bottom cover. (Refer to
“2-3. Bottom Cover and Tripod Washer”
.)
3.
Remove the inside panel assembly. (Refer to
“2-4-1. Inside Panel Assembly”
.)
4.
Remove the outside panel assembly. (Refer to
“2-5-1. Outside Panel Assembly”
.)
5.
Remove the top panel assembly. (Refer to
6.
Remove the SxS slot assembly. (Refer to
7.
Remove the front panel assembly. (Refer to
8.
Remove the rear panel assembly. (Refer to
.)
9.
Remove the IO-255 assembly. (Refer to
10. Remove the main heat spreader DCP. (Refer to
Procedure
1.
Peel off the tape (BT).
2.
Disconnect the fine-wire coaxial cable with connector from the connector CN2301 on the DCP-56 board.
3.
Disconnect the HN-404 board from the connector CN104 on the IF-1182 board.
4.
Disconnect the HN-403 board from the connector CN101 on the IF-1182 board.
5.
Remove the six precision screws (M2.6 x 5) to detach the handle assembly.
Handle assembly
Fine-wire coaxial cable
CN2301
(DCP-56 board)
CN104
IF-1182 board
HN-403 board
CN101
Precision scerws
(M2.6 x 5)
Precision scerws
(M2.6 x 5)
Precision scerws
(M2.6 x 5)
HN-404 board
Tape (BT)
6.
Install the removed parts by reversing steps of removal.
PMW-200/PMW-EX280
2-24
Summary of Contents for PMW-200
Page 1: ...SOLID STATE MEMORY CAMCORDER PMW 200 PMW EX280 SERVICE MANUAL 1st Edition Revised 1 ...
Page 4: ......
Page 8: ......
Page 10: ......
Page 30: ......
Page 38: ...3 Install the removed parts by reversing steps of removal PMW 200 PMW EX280 2 8 ...
Page 82: ......
Page 96: ......
Page 128: ......
Page 130: ......
Page 132: ......
Page 133: ......