ID
Intended device
Diagnosis
Error value
Type1/2
Note
0x25
ExpressCard
ExpressCard power
switch ON/OFF control
Non-installation "-6" is
always returned.
1
Startup must be com-
pleted
0x26
(SlotB)
ExpressCard overcur-
rent detection
Non-installation "-6" is
always returned.
1
Startup must be com-
pleted
0x23
LED
LED blink check
Refer to "Details of di-
agnosis"
1
Startup must be com-
pleted
0x24
LED
LED blink check
Refer to "Details of di-
agnosis"
1
Startup must be com-
pleted
0x30
Torino (video signal
line)
Video encoding
Refer to "Details of di-
agnosis"
1
Startup must be com-
pleted
0x31
Torino (audio signal
line)
Audio encoding
Refer to "Details of di-
agnosis"
1
Startup must be com-
pleted
0x32
4-bit signal line
Transfer data (from
Ramiel) check
Refer to "Details of di-
agnosis"
1
Startup must be com-
pleted
0x01
—
Command response on-
ly
Normal end "0" is al-
ways returned.
2
Startup must be com-
pleted
Details of diagnosis
Error value
Diagnosis
0
Normal end
-1
Hardware error detected
-4
Service tool not detected
-6
Non-installation
Item4 (Audio block diagnosis)
The audio block diagnosis tests the following content.
ID
Diagnosis
Error value
Type1/2
Note
0x11
Audio memory area check (in the
CXD9211CGG (Main T-one))
-1: Memory read/write comparison
error
1, 2
—
0x12
FPGA (ANDA) access check
(AU-342 board IC501 A6 pin, A4
pin, A7 pin, A5 pin)
-1: Register set value acquisition er-
ror
1, 2
—
0x13
DSP-only DPSRAM check
Other than 0: DPSRAM check error
1, 2
—
Error number of failed diagnosis is
displayed as an error value. For error
values, refer to "Error values of di-
agnosis items ID 0x13".
0x14
Serial audio data check in the audio
block
Other than 0: Mismatch between out-
put data and input data
1, 2
This diagnosis using an
internal microphone
may fail depending on
disturbing noise.
Error number of failed diagnosis is
displayed as an error value. For error
values, refer to "Error values of di-
agnosis items ID 0x14".
0x15
Serial audio data reception check of
IC1700 on the DCP-56 board
Other than 0: Mismatch between out-
put data and input data
1, 2
—
Error number of failed diagnosis is
displayed as an error value. For error
values, refer to "Error values of di-
agnosis items ID 0x15".
PMW-200/PMW-EX280
3-8
Summary of Contents for PMW-200
Page 1: ...SOLID STATE MEMORY CAMCORDER PMW 200 PMW EX280 SERVICE MANUAL 1st Edition Revised 1 ...
Page 4: ......
Page 8: ......
Page 10: ......
Page 30: ......
Page 38: ...3 Install the removed parts by reversing steps of removal PMW 200 PMW EX280 2 8 ...
Page 82: ......
Page 96: ......
Page 128: ......
Page 130: ......
Page 132: ......
Page 133: ......