9.
Disconnect the MIC unit from the connector CN100 on the FP-179 board.
Tapping screw
(2 x 5)
Precision screw
(M2 x 4)
FP-179 board
Tapping screw
(2 x 5)
MIC unit
MIC case
CN100
CN100
(KSW-62 board)
10. Install the removed parts by reversing steps of removal.
2-13-4. EVF Case Assembly
Preparation
1.
Remove the battery lid. (Refer to
2.
Remove the bottom cover. (Refer to
“2-3. Bottom Cover and Tripod Washer”
.)
3.
Remove the inside panel assembly. (Refer to
“2-4-1. Inside Panel Assembly”
.)
4.
Remove the outside panel assembly. (Refer to
“2-5-1. Outside Panel Assembly”
.)
5.
Remove the top panel assembly. (Refer to
6.
Remove the SxS slot assembly. (Refer to
7.
Remove the rear panel assembly. (Refer to
.)
8.
Remove the handle (upper) case assembly. (Refer to
“2-13-2. Control Switch Block (GZ92000)”
.)
Procedure
1.
Remove the two precision screws (M2 x 5) to detach the handle rear cabinet assembly.
2.
Remove the four precision screws (M2 x 4) to detach the rear (cold) shoe.
3.
Disconnect the harness from the connector CN101 on the DR-670 board.
4.
Remove the EVF harness sheet.
PMW-200/PMW-EX280
2-27