2-6-3.
EN-164/KY-706 Board
Preparation
1.
Remove the bottom panel assembly. (Refer to
2.
Remove the inside panel assembly. (Refer to
“2-6-1. Inside Panel Assembly”
)
Procedure
1.
Remove the top frame (encoder).
2.
Disconnect the harness from the connector (CN103) on the KY-706 board.
3.
Remove the two screws to detach the encoder bracket.
4.
Remove the hexagon nut and the washer to detach the EN-164 board.
5.
Disconnect the harness from the connector (CN100) on the EN-164 board.
Top frame (encoder)
Precision
screws
(P2 x 5)
Encorder bracket
Hexagon nut
EN-164 board
Harness
Washer
CN103
(KY-706 board)
CN100
6.
Disconnect the harness from the connector (CN100) on the SW-1616 board.
7.
Remove the screw to detach the KY-706 board, switch (shutter), holder (shutter), button (main) assembly, and light
guide (encoder).
8.
Reel the cushion (HN412) from the KY-706 board.
9.
Disconnect the flexible flat cable from the connector (CN100) on the KY-706 board.
10. Disconnect the harness from the connector (CN102) on the KY-706 board.
Precision screws
(P2 x 5)
KY-706 board
Holder (shutter)
Switch (shutter)
Groove
Light guide (encoder)
Button (main) assembly
Harness
Slide switch
Cushion (HN412)
CN102
CN100
Flexible flat cable
CN100 (SW-1616 board)
Note
When installing the KY-706 board, fit the slide switch with the groove of the switch (shutter).
11. Install the removed parts by reversing the steps of removal.
PMW-300
2-24