2-14. DCP-64 Board
Preparation
1.
Remove the bottom panel assembly. (Refer to
2.
Remove the inside panel assembly. (Refer to
“2-6-1. Inside Panel Assembly”
)
3.
Remove the outside panel assembly. (Refer to
“2-7-1. Outside Panel Assembly”
)
4.
Remove the rear panel assembly. (Refer to
)
5.
Remove the IO block. (Refer to
)
6.
Remove the handle assembly. (Refer to
Procedure
1.
Remove the six screws to detach the heat spreader DCP assembly.
P2 x 4
Heat spreader DCP assembly
P2 x 4
2.
Remove the screw (P2 x 4) to detach the USB GND plate.
3.
Remove the two screws (P1.7 x 4) and the screw (P2 x 4) to detach the HDMI bracket.
(a)
P2 x 4
USB GND plate
HDMI bracket
(b)
P2 x 4
(c)
P1.7 x 4
Note
When installing the USB GND plate and the HDMI bracket, tighten screws (a) to (c) in alphabetical order.
4.
Disconnect the five fine-wire coaxial cables from the five connectors on the DCP-64 board.
PMW-300