USING ANOTHER CARTRIDGE
A cartridge weighing between 4 and 12 g can be mounted with the supplied shell (7.5 g}.
Cartridge replacement 1) Lower the sound levei or turn off the amplifier.
9 Remove the Shell from the Tonearm. Q Unplug the connectors of the Shell from the four output terminals of the
cartridge.
QRe1-move the old cartridge by Foosening the two mounting
screws.
6 Install the cartridge into the shell with the supplied mounting screws so that the distance between the shell end and
the stylus tip is 49 mm (1 15';l15inches}. The temporary overhang adjustment is then complete. More precise
adjustment should be made later.
If the from edge of the shell blocks the cartridge and the required distance cannot be obtained, insert the supplied
spacer
under the shell.
Fasten the screws lighriy so that the cartridge can slide for
Spacer M adjustment.
Connect the iead wires of the shell to the corresponding pins on the cartridge.
Wires Cartridge pins
White . . . . . . . . . . . . . L {left channel signal}
Blue . . . . , , . . . . . . . . LE or G [left channel ground)
Red. . . . . . . . . . . . . . {right channel signal)
Green . . . . . . . . . . . . . RE or G (right channel ground]
B Plug the Shell into the Tcmearm and turn the Locking Collar counterclockwise until the Shell is firmly locked.
Overhang check Check that the stylus overhang is set correctly by using the Aiignment Protr-actor supplied. 0 Piace
the hole of the Alignment Protractor over the Center Spindle.
Q Bring the Tonearm above the cross point of the two fine fines, and carefully lower the stylus on the cross point with
the Cueing Lever.
9 Check to see that the Shell is parallel to the thick lines drawn on the Alignment Protractor as shown in the center
illustration. if they are parallel. the stylus overhang is set correctly.
wOverhang is too long.
Slide the cartridge backward.
Correct overhang
Overhang is Too short.
i Slide the cartridge forwflrd.
Q It the Shell is not parallel, readjust the stylus overhang.
1) Loosen the cartridge mounting screws and slide the cartridge in the required direction.
2) Re-tighten the screws.
OAdjust the Tonearm again according to the ”TONEARlVl ADJUSTMENT"
IWhBH using some other shell or cartridge different from that supplied, the total weight of the shell and the cartridge