10
REMOTE Parallel Input Port
Pin Assignment of the REMOTE Port
The REMOTE port is as a 25-pin D-SUB
connector (female).
Pin assignment and connection are as follows:
REMOTE port
1. Press the button for the desired input or
output channel.
2. Press the button for the output channel if
the button pressed in step 1 was input.
Press the button for input channel if the
button pressed in step 1 was output.
At this point, the Crosspoint is determined.
PARALLEL IN 1
PARALLEL IN 2
Pin No.
Name
Pin No.
Name
Pin No.
Name
Pin No.
Name
1
2
3
4
5
6
7
8
9
10
11
14
15
16
17
18
19
20
21
22
23
24
25
14
15
16
17
18
19
20
21
22
23
24
25
12
13
1
2
3
4
5
6
7
8
9
10
11
12
13
GND
IN 1
IN 3
IN 5
IN 7
OUT 1
OUT 3
NC
NC
GND
GND
GND
GND
GND
IN 2
IN 4
IN 6
IN 8
OUT 2
OUT 4
NC
NC
GND
GND
GND
GND
IN 9
IN 11
NC
NC
NC
NC
NC
NC
GND
GND
GND
GND
GND
IN 10
IN 12
NC
NC
NC
NC
NC
NC
GND
GND
GND
Functions of the REMOTE Port
The Crosspoint buttons of the PVS-1240S can be set from an external location using a device connected via the REMOTE port.
The OFF buttons cannot be operated via the REMOTE port.
Pin Assignment of the PVS-1240S
Switch
GND
INPUT 9~12
DC5V
DC5V
•
PARALLEL IN1
•
PARALLEL IN2
Pressing the button again allows you to change the first channel pressed, if it is of the same input or output channel group.
Operation
When setting the Crosspoint buttons via the REMOTE port, it is necessary to contact the switches of respective input and
output, rather than by directly pressing the Crosspoint buttons on the front panel.
For actual operation, perform the following steps:
NOTE
If the second button is not pressed within 5 seconds after
the first button is pressed, this unit automatically returns
to the state immediately before the first button was
pressed.
Example of Connection Circuit
The REMOTE Parallel Input port has twelve sets of A/V
input channels and four sets of output channels.
Crosspoints are determined by specifying the input and
output channels.
NOTES
• Be sure to use nonlocking-type external switches, such
as momentary switches. Using locking-type switches
will cause improper operation or malfunction.
• Use a cable no more than 50 m in length.
Switch
External switch box, etc.
GND
INPUT 1~8
OUTPUT 1~4
Summary of Contents for PVS-1240S
Page 14: ...14 ...