ND Filter Dial
If the ND filter will not move, you can move the
filter to the Clear position manually using the
following procedure.
1
Turn the camcorder POWER switch to the off
position.
2
Remove the round cap on the bottom side.
3
Insert a screwdriver in the hole and turn it
counterclockwise.
ˎ
ˎ
The ND filter moves to the Clear position by
turning counterclockwise. Continue turning
until reaching the Clear position.
ˎ
ˎ
Use a screwdriver with Ø2.4 mm diameter
or smaller. The insertion depth of the
screwdriver is about 3.2 cm (1 5/16 in.).
Screwdriver hole
(with cap removed)
4
Set the PRESET/VARIABLE switch (page 6)
to the PRESET position, and set the ND FILTER
dial (page 6) to Clear.
[Notes]
ˎ
ˎ
Do not use the procedure above during normal operation.
Only use this procedure if the ND filter will not move. The
ND filter may become damaged if this procedure is used
during normal operation.
ˎ
ˎ
After the procedure above is used, consult a Sony service
center to have the camcorder repaired.
ˎ
ˎ
If an error message still appears after performing the
procedure above, shooting is still possible.