2-20. Handle Assembly
Preparation
1.
Remove the outside panel assembly. (Refer to
2.
Remove the tally cover. (Refer to
)
Procedure
1.
Disconnect the fine-wire coaxial cable from the connector (CN001) on the LED-492 board.
CN001
(LED-492 board assembly)
Fine-wire coaxial cable
2.
Disconnect the harness A.
1) Disconnect the harness A from the connector (CN800) on the RE-326 board.
2) Release the harness A from the notch of the cushion (Light).
Harness A
Notch of the cushion (Light)
CN800
(RE-326 board)
PXW-X500