6-11
6-6. MECHA AGING
On the Test Mode Menu screen, selecting
[3]
executes the aging of
mechanism. First, open the tray and load a disc. Press the
H
key,
and the aging will start. During aging, the number of the repeat
cycle is displayed. Aging can be aborted at any time by pressing the
x
key. After the operation has stopped, unload the disc and press
again the
x
key or the
O
key to return to the Test Mode Menu.
6-7. EMERGENCY HISTORY
On the Test Mode Menu screen, selecting
[4]
displays the information
such as servo emergency history. The history information from last
“1” up to “10” can be scrolled with
$
key or
4
key. Also, specific
information can be displayed by directly entering that number with
the ten-key pad from
[1]
to
[9]
.
(Emergency history code is shown separately.)
The upper two lines display the laser ON total hours. Data below
minutes are omitted.
keys in this order.
Both CD and DVD data are cleared.
Clearing emergency history
Press
keys in this order.
The data have been initialized when “Set Up Initialized” message
is displayed.
The EMG. History display screen will be restored soon.
6-8. VERSION INFORMATION
The ROM version, region code, OPT type, etc. are displayed if
[5]
is selected in the Test Mode Menu. The parenthesized hexadecimal
number in the version number field indicates the checksum value of
the ROM.
* Note after Downloading
After downloading ROM data, sometimes it happens that checksum
is not the same as that of ROM data that has been downloaded.
In such a case, go back to the menu screen and select “0. Syscon
Diagnosis”, then select “1. All” in “2. Version”. If the result of this
operation does not give an agreement, it must be either Download
error or ROM error.
6-9. VIDEO LEVEL ADJUSTMENT
On the Test Mode Menu screen, selecting
[6]
displays color bars for
video level adjustment. During display of color bars, OSD disappears
but the menu screen will be restored if pressing any key.
6-10. IF CON SELF DIAGNOSTIC
FUNCTION
1. IF-92 BOARD (IF CON) TEST MODE
The front board test mode is the IF CON self diagnostic mode. The
IF CON can diagnose the functions of the front panel boards that
the IF CON controls. Normally, the IF CON makes a serial
communication with the SYSTEM CONTROL and operates
following the commands from the SYSTEM CONTROL, but in the
Test mode, the IF CON operates independently from the SYSTEM
CONTROL.
In the Test mode, the following functions can be checked.
1. Button function
2. Remote commander receiving function
3. SYSTEM CONTROL-IF CON serial communication
4. Click shuttle function
5. Fluorescent display tube lighting check
Grid check
Anode check
6. LED control function
In the Test mode, the set operates same as usual, except voltage
monitoring, communication monitoring, display of fluorescent
display tube, and LED control.
1. The routine that mo3.3 V (P-CONT) of MB-103 board
is not provided.
2. The monitoring timer for serial communication with the
SYSTEM CONTROL is not provided. The set is not placed in
the Standby mode, even if the communication with SYSTEM
CONTROL is normal.
3. Display of fluorescent display tube (normally, display is made
following the commands from SYSTEM CONTROL)
4. LED control (normally, control is made following the commands
from SYSTEM CONTROL)
### Mecha Aging ###
Press OPEN key
Abort : STOP key
### EMG. History ###
Laser Hours
CD
xxhxxm
DVD
xxhxxm
1.
00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
2.
00 00 00 00 00 00 00 00
00 00 00 00 00 00 00 00
Select : 1-9
Scroll : UP/DOWN
(1: Last EMG.)
Exit
: RETURN
### Version Infomation ###
IF con.
Ver.x.xxx(xxxx)
Group
xx
SYScon.
Ver.x.xxx(xxxx)
Model
xx
Region
0x
Servo DSP Ver:x.xxx
AVD ucode Ver:xxxxxxxx
OPT TYPE : x LASER
Exit : RETURN
www. xiaoyu163. com
QQ 376315150
9
9
2
8
9
4
2
9
8
TEL 13942296513
9
9
2
8
9
4
2
9
8
0
5
1
5
1
3
6
7
3
Q
Q
TEL 13942296513 QQ 376315150 892498299
TEL 13942296513 QQ 376315150 892498299