7-6
3. Overall Level Characteristic and Distortion Factor
Check
Purpose:
Check the record level, play level, and distortion factor against the
reference input.
Mode
REC and PB (SP mode)
Signal
400 Hz, –6.3 dBs
Measurement point
Audio output terminal
Measurement equipment
Audio level meter and
distortion factor meter
Specified value
Playback level: –6.3 ± 2 dBs
Distortion factor: 1% or less
Confirmation Method:
1) Supply an audio signal of 400 Hz, –6.3 dBs simultaneously to
both L and R channels of Audio Line Input.
2) Make recording
3) Play back a recorded portion.
4) Confirm that a playback level is –6.3 dBs.
5) Confirm that a distortion factor is within 1%.
4. Overall S/N Check
Purpose:
Confirm that the S/N is within the specification.
Mode
REC and PB (SP mode)
Signal
No signal
Measurement point
Audio output terminal
Measurement equipment
Audio level meter
Specified value
–67.5 dBs or less
Confirmation Method:
1) Connect both L and R channels of audio line input to the GND.
2) Start recording.
3) Play the recorded part to confirm that the noise is below –67.5
dBs.
2-5-2.
Normal Audio System Adjustment
• Make adjustment in the SP mode, unless otherwise specified.
Use a normal VHS cassette for an adjustment tape.
• Set AUDIO MONITOR to normal.
[Adjustment Sequence]
1. ACE Head Adjustment
2. E-E Output Level Check
3. Frequency Responce Check
4. Overall Level Characteristic and Distortion Factor
Check
5. Overall S/N Check
1. ACE Head Adjustment
Refer to the service manual of VHS MECHANICAL
ADJUSTMENT
IV
.
2. E-E Output Level Check
Purpose:
Confirm that the output level against the reference input is within
the specification.
Mode
E-E
Signal
L, R: 400 Hz, –6.3 dBs
Measurement point
Audio output terminal
Measurement equipment
Audio level meter
Specified value
–6.3 ± 2 dBs
Confirmation Method:
1) Simultaneously input a signal of 400 Hz, –6.3 dBs to both L
and R channels of Audio Line Input.
2) Confirm that the audio output level is –6.3 ± 2 dBs.
3. Frequency Responce Check
Purpose:
Confirm that the frequency characteristic is within the specifica-
tion.
Mode
REC and PB (SP mode)
Signal
400 Hz, –26.3 dBs
7 kHz, –26.3 dBs
Measurement point
Audio output terminal
Measurement equipment
Audio level meter
Specified value
0 ± 3 dB
Tape path adjustment must have been completed.
Confirmation Method:
1) Supply a signal of 400 Hz, –26.3 dBs to both L and R chan-
nels of Audio Line Input.
2) Connect the audio level meter to the Audio Line Output.
3) Adjust the attenuator so that the audio level meter will indi-
cate –26.3 dBs.
4) Make recording in the SP mode.
5) Set an audio line input signal to 7 kHz and make recording.
6) Playback a recorded portion, and measure output levels at 400
Hz and 7 kHz.
7) Confirm that the 7 kHz playback output level within a range
of the 400 Hz playback output level 0 ± 3 dB.
Summary of Contents for RMT-V220B
Page 7: ...1 2 ...
Page 8: ...1 3 ...
Page 9: ...1 4 ...
Page 10: ...1 5 ...
Page 11: ...1 6 ...
Page 12: ...1 7 ...
Page 13: ...1 8 ...
Page 14: ...1 9 ...
Page 15: ...1 10 ...
Page 16: ...1 11 ...
Page 17: ...1 12 ...
Page 18: ...1 13 ...
Page 19: ...1 14 ...
Page 20: ...1 15 1 15 E ...
Page 25: ......
Page 26: ......
Page 27: ......
Page 28: ......
Page 29: ......
Page 30: ......
Page 31: ......
Page 32: ......
Page 33: ......
Page 34: ......
Page 35: ......
Page 36: ......
Page 37: ......
Page 38: ......
Page 39: ......
Page 40: ......
Page 41: ......
Page 42: ......
Page 43: ......
Page 44: ......
Page 45: ......