54
Status
Ch
apt
er 1 U
s
e
r G
u
id
e
Projector. “Battery” indicates the status of the Projector’s
Secure Silicon battery.
Lamp Status
The SRX-R320
projectors are single
lamp systems. To access
the Status pane for the
Projector Lamp, tap
Menu
, tap
Status
and
then tap
Lamp
.
The LAMP pane appears
which displays both
Lamp and Projector
hours of use and the Date
of the most recent Lamp
Replacement.
In addition, Status
indicators are present for the following:
• Lamp Timer Alert
• Lamp Ballast
• Lamp Z-Axis
• Luminance Adjustment
• Luminance Adjust Limit
The STATUS button shown to the right
appears on all Projectionist Terminal
windows and provides immediate access to
the combined Status Warning indicators and selector
buttons. When any Warning condition exists the STATUS
button will appear RED as shown. To view which system
area requires attention, tap the
STATUS button
and the
Status Warning/Selector buttons appear.
As illustrated to the right, the Lamp
Selector/Warning indicator will be RED
when an error condition exists. To view the
Lamp Status, tap the
Lamp Warning
icon.
Lamp Information
This Lamp Information group shows the Lamp Hours,
total Operation Hours (projector), Lamp ON Timer, and
the most recent date the lamp was REPLACED.
Lamp Hours
The value shown for Lamp Hours is an effective value
which uses the Lamp Power value to adjust the actual
Lamp ON hours downward when operating the lamp at
less than 100% power. This value is reset to “0” (zero)
when the lamp is replaced and a new Lamp Serial Code is
entered.
Operation Hours
The value shown for Operation Hours is the total number
of hours when AC Mains are applied to the Projector.
Total Lamp ON Hours
The value shown for Total Lamp ON Hours is the actual
number of hours when the Lamp is in the ON mode.
The lamp should be replaced prior to exceeding
recommended operating hours. Refer to the projector
documentation for additional information.
Lamp Indicators
Lamp Timer Alert
The Lamp Timer Alert is green when the lamp hours are
less than the recommended operating hours. The indicator
will display yellow when the hours are exceeded.
Lamp Ballast
The indicator is green when the status of the power
(ballast) for the projection lamp is normal. The indicator
will display red when an error is detected.
Lamp Z-Axis Adjust
The Lamp Z-Axis indicator is green when the status the
Z-axis adjustment motor used for lamp positioning is
normal. The indicator will display yellow when an error is
detected.
Luminance Adjust
The Luminance Adjust indicator is green when the
luminance adjustment feature is operating normally. The
indicator will display yellow when an error is detected.
Luminance Adjust Limit
This indicator is reserved for future expansion of projector
features. Currently this indicator is green at all times.
Tap Lamp
Status Menu
Lamp Information
Lamp Timer Alert
Lamp Ballast
Lamp Z-Axis
Luminance Adjustment
Luminance Adjust Limit
Lamp
Hours
Operation Hours
(Lamp) Replaced
Total Lamp ON
Hours
Note
Summary of Contents for Screen Management System
Page 81: ...Sony Corporation ...