17-4
6
SYN LED
The SYN LED display is as follows in the synchronizing mode:
Status
During synchronous recording
During synchronous playback
During synchronous playback chase
During STOP, FF and REW
During self-check
Master
Lit
Blinking
Off
Slave
Lit
Blinking
Off
Status
Master POWER OFF
Slave POWER OFF
Cable connection trouble
MST/SLV switch incorrectly set
No data to be synchronized
Slave
LCD screen SYN LED
—
Off
Off
Off
EX30
Blinking
—
Off
EX31
Off
7
Trouble
If trouble occurs while the sync cable is connected, the display screen and the SYN
LED appear as follows:
Master
LCD screen
SYN LED
Off
Off
EX30
Off
EX30
Blinking
—
Off
—
Blinking
(Operate independently)
Note
•
When cable connection trouble occurs, and the power switches of the recorders have
been turned OFF and then ON again, the recorders do not enter the synchronizing
mode, but operate independently.
•
“MST/SLV switch incorrectly set” means that both recorders are set as “master” or
“slave”.
•
“No data to be synchronized” means that there is no data to be synchronized on the
slave’s tape.