– 10 –
2-2. Machine Test Mode Input/Output
2-2-1. Input (Input ports for other than main tasks)
2-1. Channel Setting
During startup in machine test mode, make the following channel settings by loading the terminal input data.
2-2-2. Output (Output ports for other than main tasks)
Pin Name
Pin No.
Function
Logic
ROW 1 – ROW 5
@ª
,
Setting the CH (channel)
Refer to channel setting
#¡
–
#¢
TEST CH
1
Control terminal for setting the CH (channel)
H: OFF, L : ON
TEST SW
$º
Start up of test mode
H : Start, L : No start
TEST ACT
$¢
During test mode, causes start of intermittent operation
H : Intermittent start
with external input.
Pin No.
#¢
#£
#™
#¡
@ª
TX EREQUENCY
RX EREQUENCY
Channel
ROW 5
ROW 4
ROW 3
ROW 2
ROW 1
(MHz)
(MHz)
CH1
H
L
L
L
L
43.720
48.760
CH2
H
L
L
L
H
43.740
48.840
CH3
H
L
L
H
L
43.820
48.860
CH4
H
L
L
H
H
43.840
48.920
CH5
H
L
H
L
L
43.920
49.020
CH6
H
L
H
L
H
43.960
49.080
CH7
H
L
H
H
L
44.120
49.100
CH8
H
L
H
H
H
44.160
49.160
CH9
H
H
L
L
L
44.180
49.200
CH10
H
H
L
L
H
44.200
49.240
CH11
H
H
L
H
L
44.320
49.280
CH12
H
H
L
H
H
44.360
49.360
CH13
H
H
H
L
L
44.400
49.400
CH14
H
H
H
L
H
44.460
49.460
CH15
H
H
H
H
L
44.480
49.500
CH16
L
L
H
H
L
44.610
49.670
CH17
L
L
H
H
H
44.630
49.845
CH18
L
H
L
L
L
44.670
49.860
CH19
L
H
L
L
H
44.710
49.770
CH20
L
H
L
H
L
44.730
49.875
CH21
L
H
L
H
H
44.770
49.830
CH22
L
H
H
L
L
44.830
49.890
CH23
L
H
H
L
H
44.870
49.930
CH24
L
H
H
H
L
44.930
49.990
CH25
L
H
H
H
H
44.970
49.970
TEST1
L
L
L
H
L
43.780
48.800
TEST2
L
L
L
H
H
43.890
48.970
TEST3
L
L
H
L
L
46.800
49.910
TEST4
L
L
H
L
H
46.900
49.950
Pin Name
Pin No.
Function
H Logic
L Logic
TALK LED
$•
Various input/output monitor output (default : RSSI(H)
No detection
Detection
detection).
KEY LED
2
During test mode : All lights lit, However, does not include
No light
Light
(SPP-850/860 only)
measurement of consumption current.