[Switch • LED Test]
• This mode is activated when
[ANSWER]
key is pressed in the
Test Mode Idle status.
1.
[DIAL MODE]
switch test
T (TONE) side : ANSWER LED ON
P (PULSE) side : ANSWER LED OFF
2.
[RINGER SELECT]
switch test
3 (3-time terminating setting) : CHARGE/IN USE LED ON
TS (Toll Saver)
:
CHARGE/IN USE LED OFF
ANN ONLY
:
[Dial • Auto Hold Reset • Charge Test]
• This mode is activated when
[REPEA T]
key is pressed in the Test
Mode Idle status.
1. Dial test
Each time
[REPEA T]
key is pressed, the following dial signals
are transmitted:
“0” of PULSE
→
“1” of DTMF
→
“#” of DTMF
↑
2. Hold reset test
The ANSWER LED turns on when the hold reset detection port
is in “High” status, or turns off when “Low”. (Once the “Low”
is detected, “Low” is kept during the Test mode.)
3. Charge detection test
The CHARGE LED turns on at Charge ON, or turns off at
Charge OFF.
[C-ID Test]
• This mode is activated when
[PLA Y/ST OP]
key is pressed in the
Test Mode Idle status.
• ”0" is displayed on the 7-SEG LED where the public network
terminating mode is activated so as to receive a call ID.
• When a call ID was received, checksum is judged, and “1” is
displayed on 7-SEG LED if matched, or “0” is still displayed if
not matched.
3-2.
HANDSET
[Start-up method]
1. Starting with POWER ON
• Reset the POWER ON with TEST SW pin (IC501
#™
pin)
in “H” status, and the Test mode starts.
2. Starting from Idle status
• In the Idle status, press
[TALK]
,
[0]
and
[7]
keys at the same
time, and the Test mode starts.
3. Operation at start-up
• When the Test mode starts, the Handset causes the ringer to sound
for 500ms, sets a channel depending on the key matrix condition
so as to be ready for receiving.
Also, the Handset sets the Liquid cristal display all turn on, the
RSSI gain to High, and goes in the Test Mode Idle status.
• For the COL0~COL3 logic of key matrix and channel setting,
refer to the frequency table.
[Operation in Test Mode Idle status]
1. RSSI monitoring
• The RSSI is always monitored at IC501
$™
pin (SIG-IN).
(RSSI is present: SIG-IN = “Low”, RSSI is not present: SIG-
IN = “High”)
2.
[RING ON/OFF]
switch monitoring
• In the Test mode, the RING MODE port is always monitored
at IC501
7
pin (RING MODE), and if RING is ON (RING
MODE = “High”), the buzzer volume is increased, or if RING
is OFF (RING MODE = “Low”), the buzzer volume is re-
duced.
3. Key input monitoring
In the Test Mode Idle status, key input is always monitored,
and a key touch tone is generated each time a key is pressed,
then respective modes are activated according to the key pressed.
HAND SET FREQUENCY TABLE
!•
!∞
!§
!¶
RX FREQUENCY TX FREQUENCY
COL3 COL2 COL1 COL0
(MHz)
(MHz)
Channel
Pin No.
1CH
0
0
0
0
43.720
48.760
2CH
0
0
0
1
43.740
48.840
3CH
0
0
1
0
43.820
48.860
4CH
0
0
1
1
43.840
48.920
5CH
0
1
0
0
43.920
49.020
14CH
0
1
0
1
44.460
49.460
15CH
0
1
1
0
44.480
49.500
16CH
0
1
1
1
46.610
49.670
17CH
1
0
0
0
46.630
49.845
23CH
1
0
0
1
46.870
49.930
24CH
1
0
1
0
46.930
49.990
25CH
1
0
1
1
46.970
49.970
T1CH
1
1
0
0
43.780
48.800
T2CH
1
1
0
1
43.890
48.970
T3CH
1
1
1
0
46.800
49.910
T4CH
1
1
1
1
46.900
49.950
Summary of Contents for SPP-A400 - Cordless Telephone With Answering Machine
Page 3: ... 3 This section is extracted from instruction manual SECTION 1 GENERAL ...
Page 4: ... 4 ...
Page 5: ... 5 ...
Page 6: ... 6 ...
Page 7: ... 7 ...
Page 8: ... 8 ...
Page 9: ... 9 ...
Page 10: ... 10 ...
Page 11: ... 11 ...
Page 12: ... 12 ...
Page 13: ... 13 ...
Page 14: ... 14 ...
Page 15: ... 15 ...
Page 16: ... 16 ...
Page 17: ... 17 ...
Page 18: ... 18 ...
Page 19: ... 19 ...
Page 20: ... 20 ...
Page 33: ......
Page 34: ......
Page 35: ......
Page 36: ......
Page 37: ......
Page 38: ......