1
Command List
FCB-EH6500(GB) A-EEP-100-11(1)
Pan/Tilt Status Code List
P
Q
R
S
– – – –
– – – –
0 – – –
– – – 1
A Pan movement all the way to the left
– – – –
– – – –
0 – – –
– – 1 –
A Pan movement all the way to the right
– – – –
– – – –
0 – – –
– 1 – –
A Tilt movement all the way up
– – – –
– – – –
0 – – –
1 – – –
A Tilt movement all the way down
– – – –
– – – –
– – 0 0
– – – –
Pan movement is correct
– – – –
– – – –
– – 0 1
– – – –
Abnormal pan position detected
– – – –
– – 0 0
0 – – –
– – – –
The Tilt movement is correct
– – – –
– – 0 1
0 – – –
– – – –
Abnormal tilt position detected
– – – –
0 0 – –
0 – – –
– – – –
No move request received
– – – –
0 1 – –
0 – – –
– – – –
In the midst of a Pan/Tilt
– – – –
1 0 – –
0 – – –
– – – –
Pan/Tilt completed
– – – –
1 1 – –
0 – – –
– – – –
Pan/Tilt failed
– – 0 0
– – – –
0 – – –
– – – –
Not initialized
– – 0 1
– – – –
0 – – –
– – – –
Initializing
– – 1 0
– – – –
0 – – –
– – – –
Initialization completed
– – 1 1
– – – –
0 – – –
– – – –
Initialization failed
( - : optional)
Pan/Tilt Position (for reference)
Parameter (position)
PAN
DE00 (−170 degree) to 2200 (+170 degree)
TILT
FC00 (−20 degree) to 1200 (+90 degree)
(Image Flip: OFF)
EE00 (–90 degree) to 0400 (+20 degree)
(Image Flip: ON)
LED Status
Status
POWER (Green)
STANDBY (Orange)
Main power
ON
Power On
(including initializing period)
On
Off
When receiving infrared signals form Infrared Remote Commander
Blinking
Off
At position detection error
On
Blinking
Standby status
Off
On
Power off by VISCA or the Infrared Remote Commander
Main power Off
Off
Off
Initialization
error
Pan/tilt error
Blinking
Blinking
BOTTOM
switch and
SYSTEM
SELECT switch
Setting error
(Example: when the SYSTEM SELECT switch is set to position “1, 9, E
or F”)
On
On