Error Messages and Warning Messages
80
A
ppe
ndix
When the system stops operating incorrectly
because of an internal error, a warning tone
sounds and a popup window appears in the
display of the control panel with an error
message.
Tip
Only one message is displayed at one time, even if
multiple errors occur. The number of current errors
appears at the bottom of the popup window. Be sure to
check the messages for all errors.
When an error message appears
Eliminate the cause of the error, and power the
system off and on again.
If the same error message appears again when the
system is powered on, contact a Sony service
representative.
To close the error message popup window
Press the HOME button or the BACK button.
The error code is shown in the operation status
and warnings section of the HOME screen
and at the bottom left of each Setup
menu screen (model name display) until the cause
of the error is removed.
Error messages
Refer to the Maintenance Manual for more detailed
information about the content of error messages, and
about errors not listed here.
Error Messages and
Warning Messages
About Error Messages
SDI
EMP
1
L R
dB
0
-10
-20
-30
-60
EE
SDI
EMP
2
L R
SDI
EMP
3
L R
SDI
EMP
4
L R
SDI
EMP
5
L R
SDI
EMP
6
L R
SDI
EMP
7
L R
SDI
EMP
8
L R
SDI
EMP
9
L R
SDI
EMP
10
L R
SDI
EMP
11
L R
SDI
EMP
12
L R
SDI
EMP
13
L R
SDI
EMP
14
L R
SDI
EMP
15
L R
SDI
EMP
16
L R
LOCAL
EE
21:46
REMAIN
10min
PLAY LOCK
LTC INTRP
DF
EXT-LK
VTR OOOOO
16.5V
STANDARD
ENCODE
TCG
RECINHI
KEYINHI
00
H
00
M
00
S
00
F
A001C001_120530RT
MK: --:--:--:--
59.94I
1920x1080
4:2:2
ERROR
E010
E010
FAN STOP
FAN STOP
FAN Stopped
1 Error(s)/ 2 Warning(s)
Popup window displaying error message “E010:
FAN STOP” (fan stopped)
Indicates that there is one
current error message.
Indicates that there are two current
.
To view the other messages, rotate the
SELECT/ENTER dial on the control panel.
Example:
Code
Message
Meaning
E003
SY NVRAM
ERROR
Detected an FRAM
(HOURS METER and
TC related information)
checksum error.
E00B
SY-AU I/F
ERROR
Detected a
communication error
between the audio circuit
and system CPU.
E00E
SY-CP I/F
ERROR
Detected a
communication error
between the system CPU
and CP CPU.
E010
FAN STOP
Detected a cooling fan
failure.
E013
DC IN
OVERLOAD
Detected an overcurrent
condition in the power
supply input stage.
E014
DC VOLTAGE
DOWN
The power supply
voltage dropped below
the rated value.
E017
ILLEGAL
SHUTDOWN
The power was
previously turned off
without proper
unmounting (i.e.,
ejecting) of the current
card.
E018
BOARD
TEMP NG
The temperature within
the unit exceeds the rated
value.
E01B
DUPLICATE
FILES
Detected a file name
duplication.
E031
ENCODER
FAIL
The encoder has detected
a recording error.
E032
DEC ERROR
The decoder has detected
a recording file error.
E033
HD ENC
ERROR
The encoder has detected
a recording error.