3-11
SRW-5000/5500
< As seen from backside >
Mode selection plate
Search dial
Lower control panel
B3
x
14
DIAL
MFD
LCD
LED
EXIT
DIAL TEST
Dial data : 00h
Dial direction :
JOG/SHUTTLE sensor : SHUTTLE
Dial mode sensor : D-2
PANEL MAINTENANCE MENU
KEY
BEEP
OEL
KEY
DIAG
F2
F3
F4
ALT
F5
F6
F7
F8
F9
F10
F1
[F1]
(DIAL) Key
Performs the operation checks for the search dial.
Execution Procedure
1.
On the PANEL CHECK menu, press the
[F1]
(DIAL)
key.
.
The status of the search dial is displayed.
2.
Turn the search dial to check the change of the status
display.
Dial data:
The number changes as follows
by turning the search dial.
2Bh is displayed for the full
counterclockwise position.
2Ch is displayed for the full
clockwise position.
00h is displayed for the center
position.
Dial direction:
The arrow changes as follows by
turning the search dial:
8
is displayed for the right
position from the center.
7
is displayed for the left
position from the center.
(The arrow does not change from
the previous direction at the center
position.)
JOG/SHUTTLE sensor:
JOG is displayed while the search
dial is pressed.
SHUTTLE is displayed when the
search dial is released.
n
When the Dial mode sensor is D-
2, not become the indication to the
JOG mode even it the search dial
is pressed.
Dial mode sensor:
The setting status of the Dial
mode is displayed.
D-2:
The mode does not
become the JOG
mode even it the
search dial is
pressed. (factory
setting)
BETACAM: Pressing the Search
dial switches
between the SHUT-
TLE/VAR mode
(displayed as
“SHUTTLE”) and
the JOG mode
alternately.
To change the Dial mode, fix the
control panel at 90
d
position and
loosen the screw located at the
backside of the search dial. Move
the mode selection plate to the
arrow direction until it would not
go any further. The mode display
switches to BETACAM/D-2.