3-49
SRW-5000/5500
RF
OFF
EXIT
Tele-File CHECK
TOTAL PASS FAIL
READ 0 0 0
WRITE 0 0 0
OTHERS CHECK
READ
TEST
WRITE
TEST
RESET
!
Current data in Tele-File
WILL BE CHANGE.
Press [SFT]
+
[F4] to TEST.
Press only [CLR] to CANCEL.
DIAG
F1
F2
F3
ALT
F5
F6
F7
F8
F9
F10
F4
RF
OFF
RESET
EXIT
Tele-File CHECK
TOTAL PASS FAIL
READ 0 0 0
WRITE 0 0 0
OTHERS CHECK
READ
TEST
WRITE
TEST
DIAG
F2
F3
F4
ALT
F5
F6
F7
F8
F9
F10
F1
[F1]
(T-Fil CHECK) Key
Applies power to the Tele-File circuit during its adjust-
ment. Also, performs the read/write checks for the Tele-
File.
n
When the writing check is performed, the current data in
the Tele-File is changed.
To make the Tele-File ON:
1.
In the OTHERS CHECK menu, press the
[F1]
(T-Fil
CHECK) key to display the Tele-File CHECK menu.
2.
Press the
[F2]
(RF) key several times to select “ON”.
.
The Tele-File circuit is powered on.
3.
Press the
[F10]
(EXIT) key to return to the OTHERS
CHECK menu.
.
The power to the Tele-File circuit becomes OFF
(normal state).
To perform the reading check:
1.
Insert a cassette tape.
2.
In the Tele-File CHECK menu, press the
[F3]
(READ
TEST) key.
.
The check details are displayed. Pressing the
[F8]
(RESET) key returns all the values to “0”.
TOTAL:
Reading check counts
PASS:
OK counts for reading checks
FAIL:
NG counts for reading checks
To perform the writing check:
1.
Insert a cassette tape.
2.
In the Tele-File CHECK menu, press the
[F4]
(WRITE TEST) key.
3.
Press the
[F4]
(WRITE TEST) key while pressing the
[SET]
(SHIFT) key.
.
The check details are displayed. Pressing the
[F8]
(RESET) key returns all the values to “0”.
TOTAL:
Writing check counts
PASS:
OK counts for writing checks
FAIL:
NG counts for writing checks