3-54
SRW-5000/5500
NVRAM
CTL
MEMORY
CARD
EXIT
PARALLEL INPUT SETUP
No. Command
01:H 20 10 00 00 00 00 00
18:H 20 30 00 00 00 00 00
19:H 20 05 00 00 00 00 00
20:H 20 20 00 00 00 00 00
21:H 40 00 00 00 00 00 00
22:H 20 04 00 00 00 00 00
23:H 20 0F 00 00 00 00 00
34:H 20 01 00 00 00 00 00
OTHERS CHECK
DIAG
F1
F2
F3
F4
ALT
F5
F7
F8
F9
F10
F6
[F6]
(PARA-I SETUP) Key
[F7]
(PARA-O SETUP) Key
Changes the setup data (function settings for input/output
pins) of the 50-pin parallel remote interface.
Also, displays the logic levels of the input/output pins.
How to change setting data
n
Inadvertent change to the set up data may cause trouble. To
change setting data, be sure to refer to the interface manual
for parallelremote (50-pin) of the unit.
If you change the setup data inadvertently, press the
[F1]
(NVRAM CONTROL) key to execute “ALL DATA
PREVIOUS”, or turn off the power of the unit without
executing NVRAM CONTROL.
Strictly avoid to execute SAVE ALL DATA command.
1.
On the OTHERS CHECK menu, press the
[F6]
(PARA-I SETUP) key or
[F7]
(PARA-O SETUP) key
to display the PARA-I SETUP/PARA-O SETUP
menu.
Descriptions of indications
“No.” column displays pin numbers. Also, displays H
(Hight) or L (Low) on the right of the pin number as a
logic level.
EXIT
HOURS METER
OPERATION 1132 HOURS
DRUM RUNNING 239 HOURS
TAPE HOURS 154 HOURS
THREADING 4084 T I M E S
Press SFT
+
F7 key to reset.
OTHERS CHECK
CLEAR
DIAG
F1
F2
F3
F4
ALT
F6
F7
F8
F9
F10
F5
[F5]
(HOURS METER) Key
Displays and resets the resettable hours meter and the
thread counter.
Execution Procedure
n
When the settings are reset by pressing the
[F7]
(CLEAR)
key while pressing the
[SFT]
(SHIFT) key, they are not
returned to the previous settings.
1.
On the HOURS METER menu, press the
[F5]
(HOURS METER) key to display the OTHERS
CHECK menu.
OPERATION:
Total power-distribution hours
DRUM RUNNINNG: Total drum-running hours
TAPE HOURS:
Total tape-running hours
THREADING:
Total threading counts
2.
Select an item to be reset, using
[(]
/
[)]
key or the
MULTI CONTROL knob.
3.
Press the
[F7]
(CLEAR) key while pressing the
[SFT]
(SHIFT) key to reset the value being displayed.
4.
Press the
[F10]
(EXIT) key to return to the NET-
WORK SETUP menu.