3-72
SRW-5000/5500
RF SW
POS SR
RF SW
POS HD
F1
F2
F3
F4
DIAG
ALT
F5
F6
F7
F8
F9
F10
NVRAM
CTL
CAPSTN
GAIN
EXIT
ALT SERVO ADJUST
T REEL
GAIN
TENSN
OFFSET
CAPSTAN QPL GAIN
Press SET key.
ALT SERVO ADJUST
CAPSTAN QPL GAIN
Auto Adjusting. . .
ALT SERVO ADJUST
CAPSTAN QPL GAIN
Auto Adjust Complete
[SET]
Execution Procedure
The following procedure describes the adjustment for the CAPSTAN QPL GAIN
menu.
Adjust the other menus using the same procedure.
1.
In the ALT SERVO ADJUST menu, press the
[F2]
(CAPSTN GAIN) key to
display the CAPSTAN QPL GAIN menu.
2.
Press the
[SET]
key.
.
Pressing the
[SET]
key starts the automatic adjustment. (About 20 seconds)
.
The message “Auto Adjusting...” is displayed during adjustment.
3.
Confirm the result of the adjustment.
.
When the adjustment is completed normally, the message “Auto Adjust
Complete” is displayed.
n
If “Auto Adjust Failure” is displayed, refer to “For Automatic Adjustment
Failure”on page 3-75.
4.
To save the adjusted data, press the
[F1]
(NVRAM CTL) key to display the
NV-RAM CONTROL menu, and execute “SAVE ALL DATA”.
SRW-5500