5-40
SRW-5000/5500
Capstan motor
Capstan motor
Hole
Harness
.
Upper side
.
Bottom side
PWH3
x
8
PWH3
x
8
Remove/Attach the Capstan Motor
3. Removing the Capstan Motor
(1) Disconnect the harness from the connector on
the capstan motor. (Bottom side)
(2) Remove the two screws while holding the
capstan motor by hand.
n
Be careful not to drop the capstan motor.
(3) Remove the capstan motor.
Installation
4. Attaching the Capstan Motor
(1) Pass a new capstan motor through the hole of
the MD base assembly positioning as shown
in the figure.
n
Be careful not to damage the capstan motor
shaft when passing the capstan motor through
the hole of the MD base assembly.
(2) Tighten the two screws while holding the
capstan motor by hand.
Tightening torque: 78.4
x
10
_
2
N
.
m
{8.0 kgf
.
cm}
(3) Reconnect the harness disconnected in (1) of
step 3 to the connector of the capstan motor.