7-19
SRW-5000/5500
5. TC Insert Cross-talk Adjustment
1.
Insert the Betacam cassette tape that recorded the no
signal to the LAU tracks.
2.
Set the audio analyzer as follows:
Function mode: LEVEL
Input filter:
80 kHz LPF
3.
Connect the audio analyzer’s input to CUE OUT CH2
connector.
4.
Press the
[F4]
(INC TC) key of the HOME menu
several times to set the TC insert editing mode to ON.
5.
Press the PLAY button, then press the EDIT button.
6.
Adjust the cross-talk level on the audio analyzer.
(Alternately adjust the following adj. points.)
Adj. points:
1
RV701/AE-31H (A-3)
1
RV703/AE-31H (A-3)
Specification: Minimize
(The level should be less than
_
18 dBu)
7.
Stop the recording, then eject the cassette tape.
1
2
3
4
5
6
A
B
C
D
E
F
RV500
RV100
RV203
RV103
RV702
RV700
RV703
RV701
TP100
RV202
RV201
RV200
RV205
RV204
TP202
TP201
TP401
TP400
RV401
E600
TP601
RV400
TP300
RV300
TP200
TP500
E100
RV101 RV102
S100
LV400
LV600
T500
E500
S200
AE-31H Board (Side A)
7-3-5. CUE REC System Adjustment/CUE-13/
AE-31H Boards (SRW-5500 only)
Tools
.
Audio signal generator:
Tektronix SG5010 or equivalent
.
Audio analyzer:
Audio Precision System One/Two or equivalent
.
Audio level meter:
Hewlett-Packard HP3400A or equivalent
.
Oscilloscope:
Tektronix TDS460A or equivalent
.
Frequency counter:
Advantest TR5821 or equivalent
.
Extension board: EX-949
.
Shorting clip
.
Recording tape:
BCT-HD (HDCAM cassette tape)
Preparation
1. Conditions to be kept are:
.
Resetting all the switch settings of the CUE-13 board to
the factory settings. (Refer to “7-3-2. Common Prepara-
tion”.)
.
Extension of the CUE-13 board.
.
Opening of the AE-31H board.
.
Cleaning the AT head.
.
Check of the other settings. (Refer to “7-3-2. Common
Preparation”.)
.
Warming up of equipment to be used (20 minutes or