8-13
SRW-5000/5500
1. HDCAM SR Format
Tools
.
Alignment tape:
HR5-1B
.
Recording tape:
BCT-SR series
Playback system adjustment
1.
Activate the ALT MAINTENANCE menu, and
display the RF ADJUST menu.
(HOME menu
→
[SFT]
+
[DIAG]
→
[SFT]
+
[F8]
→
[ALT]
→
[F7]
→
RF ADJUST menu)
(For the RF ADJUST menu, refer to Section 3-4-5.)
2.
Press the
[F1]
(FMT SEL) key several times to select
the HDCAM SR.
3.
Press the
[F2]
(RF ALL ADJ) key to display the RF
ALL ADJUST menu.
4.
Insert the alignment tape HR5-1B, then rewind it to the
tape beginning.
5.
To execute the automatic adjustments for PB system,
press the
[SET]
key.
.
After 20 minutes, the PB system adjustments are
completed.
6.
After the message “Continue REC CURRENT ?” is
displayed, eject the alignment tape, and then insert the
recording tape.
Record system adjustment
7.
To execute the automatic adjustment for the recording
system, press the
[SET]
key.
.
After 10 minutes, the recording system adjustments
are completed, then the message [NG List : Total 0]
is displayed.
Saving the Data
n
Do not save the adjustment data if any automatic adjust-
ment was not completed properly.
8.
Press the
[F1]
(NVRAM CTL) key to display the NV-
RAM CONTROL menu.
9.
Select the “SAVE ALL DATA” by pressing the cursor
keys, then press the
[F10]
(EXIT) key to saving data.
.
The message “Save Complete” will be displayed
when this data save is completed normally.
10. Eject the recording tape.
11. When the next adjustment “2. HDCAM Format” is not
performed, exit the maitenance mode and perform the
“4. Adjustment in the 25 Hz Mode”.
2. HDCAM Format
n
When performing this adjustment continuously from “1.
HDCAM SR Format” start this adjustment from step 2.
Alignment tape:
HR5-1A
Playback system adjustment
1.
Activate the ALT MAINTENANCE menu, and
display the RF ADJUST menu.
(HOME menu
→
[SFT]
+
[DIAG]
→
[SFT]
+
[F8]
→
[ALT]
→
[F7]
→
RF ADJUST menu)
(For the RF ADJUST menu, refer to Section 3-4-5.)
2.
Press the
[F1]
(FMT SEL) key several times to select
the HDCAM. When performing this adjustment
continuously from “1. HDCAM SR Format”, press the
[F2]
(FMT SEL) key several times and perform step 4
and later.
3.
Press the
[F2]
(RF ALL ADJ) key to display the RF
ALL ADJUST menu.
4.
Insert the alignment tape HR5-1A, then rewind it to
the tape beginning.
5.
To execute the automatic adjustments, press the
[SET]
key.
.
After 5 minutes, the adjustments are completed, then
the message [NG List : Total 0] is displayed.
Record system adjustment (SRW-5500 only)
6.
To execute the automatic adjustment for the recording
system, press the
[SET]
key.
.
After 10 minutes, the recording system adjustments
are completed, then the message [NG List : Total 0]
is displayed.