2-12
SRW-5000/5500
ERROR-20 CC TIME OVER
Description:
Malfunction of cassette compartment-up or down operation was detected.
Detecting condition:
When no operation is completed within about six seconds after operation start.
Sub error message:
None
Possible causes:
.
Cassette compartment block trouble
.
Harness (CL-29 board – DR-508 board) trouble
.
Cassette compartment motor drive circuit (DR-508 board) trouble
.
Cassette-down sensor (CL-29 board) trouble
.
Cassette-down input port (IC100 on DR-508 board) trouble
Protecting operation:
Stops the movement of the cassette compartment and reel table until a cassette
eject button is pushed.
ERROR-21 SHIFT TIME OVER
Description:
Malfunction of movement of the reel table corresponding to the cassette size was
detected.
Detecting condition:
When no operation is completed within about 18 seconds after operation start.
Sub error message:
None
Possible causes:
.
Reel shift mechanism trouble
.
Reel shift motor trouble
.
Reel shift motor drive circuit (IC501 on DR-508 board) trouble
.
Reel position sensor (PH203, PH204 on DR-508 board) trouble (S position
sensor or L position sensor)
.
Reel position input port (IC100 on DR-508 board) trouble
Protecting operation:
Stops the movement of the reel table and ejects the cassette during cassette
loading.