SERVICE MANUAL
Sony Corporation
Home Audio Division
Published by Sony Techno Create Corporation
AEP Model
UK Model
E Model
Australian Model
MULTI CHANNEL AV RECEIVER
9-887-233-03
2007H16-1
© 2007.08
SPECIFICATIONS
STR-DE400
Manufactured under license from Dolby Laboratories.
“Dolby”, “Pro Logic” and the double-D symbol are trademarks of
Dolby Laboratories.
“DTS” and “DTS Digital Surround” are registered trademarks of
Digital Theater Systems, Inc.
— Continued on next page —
Amplifier section
Models of area code AEP, UK, TW, AUS
Stereo Power Output
1)
, Reference Power
Output
1)2)
6 ohms 20 Hz – 20 kHz, THD 0.09%
55 W + 55 W, 80 W/ch
6 ohms 1 kHz, THD 0.7%
90 W + 90 W, 100 W/ch
6 ohms 1 kHz, THD 10%
120 W + 120 W, 140 W/ch
Models of area code TH
Models of area code RU
Stereo Power Output
1)
, Reference Power
Reference Power
Output
1)2)
Output
1)2)
6 ohms 20 Hz – 20 kHz, THD 0.09%
40 W + 40 W
1)
,
35 W + 35 W
3)
, 60 W/ch
6 ohms 1 kHz, THD 0.7%
65 W + 65 W
1)
,
60 W + 60 W
3)
, 80 W/ch
6 ohms 1 kHz, THD 10%
85 W + 85 W
1)
,
6 ohms 1 kHz, THD 10%
100 W/ch
75 W + 75 W
3)
, 100 W/ch
Models of area code KR
Stereo Power Output
1)
, Reference Power
Output
1)2)
6 ohms 20 Hz – 20 kHz, THD 0.09%
55 W + 55 W
1)
,
50 W + 50 W
3)
, 80 W/ch
6 ohms 1 kHz, THD 0.7%
90 W + 90 W
1)
,
80 W + 80 W
3)
, 100 W/ch
6 ohms 1 kHz, THD 10%
120 W + 120 W
1)
,
100 W + 100 W
3)
,
140 W/ch
1)
Measured under the following conditions:
2)
Reference power output for front, center and
surround. Depending on the sound field settings
and the source, there may be no sound output.
3)
Measured under the following conditions:
Frequency response
Analog
10 Hz – 70 kHz
+0.5/–2 dB (with sound
field and tone bypassed)
Inputs
Analog
Sensitivity: 800 mV/
50 kohms
S/N
4)
: 96 dB
(A, 800 mV
5)
)
Digital (Coaxial) Impedance: 75 ohms
S/N: 100 dB
(A, 20 kHz LPF)
Digital (Optical)
S/N: 100 dB
(A, 20 kHz LPF)
Outputs (Analog)
AUDIO OUT
Voltage: 800 mV/
10 kohms
SUB WOOFER
Voltage: 2 V/1 kohm
Tone
Gain levels
±
6 dB, 1 dB step
4)
INPUT SHORT (with sound field and tone
bypassed).
5)
Weighted network, input level.
Area code
Power requirements
AEP, UK, KR,
TH, RU
230 V AC, 50 Hz
AUS
240 V AC, 50 Hz
TW
110 V AC, 60 Hz
Area code
Power requirements
KR, TH
220 V AC, 50 Hz