1-85
VPH-G90E/G90U/G90M
108
Adjustments
Adjustments
Adjusting the Registration
Adjusting the Red Registration
Adjust the red signal so that it converges with the green signal and is seen
as yellow.
Note
When you have adjusted the red registration data and have saved the
adjustment data, reset the red centering to the factory preset level.
For resetting, see page 138.
7
Red CENT (centering) adjustment
Adjust so that the center of the red CROSS HAIR pattern is aligned with
that of the green CROSS HAIR pattern.
1
Press the CENT key.
The CROSS HAIR pattern and the cursor appear.
2
Press the ADJ R key.
3
Press the CUT OFF B key to display green and red.
4
Reset the FINE centering data.
See “Resetting the Data” on page 138.
5
Press the arrow keys to align the center of the red CROSS HAIR
pattern with that of the green pattern.
6
If the centers do not converge, press the CENT key again.
The projector enters the FINE centering mode for fine adjustment.
Each time you press the CENT key, the COARSE mode and FINE
mode are selected alternately, and you can use the two modes
appropriately. The adjustment data is stored for each mode separately.
While you hold down the arrow key in the FINE mode, “f” is displayed
around the adjustment position.
7
Press the arrow keys to align the center precisely.
Notes
• If the red vertical line is not aligned with that of the green pattern, adjust
the red CRT conversion angle again.
For details, see “Adjusting the CRT Conversion Angle” on page 22.
• If the upper, lower, left or right part of the screen is de-focused, adjust the
red scheimpflug again.
For details, see “Adjusting the green scheimpflug” on page 83.
Adjustments
109
Adjustments
8
Red SIZE and LIN (linearity) adjustments
1
Press the LIN key.
The CROSS HAIR pattern appears.
You can also change to the 9
×
9 HATCH pattern by pressing the
PATTERN key.
2
Press the ADJ R key.
Pay attention only to the encircled portions in the illustration on the
left.
3
Reset the FINE linearity data.
See “Resetting the Data” on page 138.
4
Adjust with the
B
and
b
keys until the parts (
a
) (distances between
the red and green lines) on the left and right are of equal length.
B
: The left and right vertical lines are shifted to the left while the
vertical center line remains unmoved.
b
: The left and right vertical lines are shifted to the right while the
vertical center line remains unmoved.
5
Press the SIZE key.
6
Reset the FINE size data.
See “Resetting the Data” on page 138.
7
Adjust with the
B
and
b
keys so that the red and green lines in the
right and left encircled portions converge.
B
: The horizontal scale is reduced.
b
: The horizontal scale is expanded.
8
If the lines do not converge, press the LIN or SIZE key and repeat the
adjustment by pressing the
B
or
b
key.
Each time you press the LINE or SIZE key, the COARSE mode and
FINE mode are selected alternately, and you can use the two modes
appropriately. The adjustment data is stored for each mode separately.
While you hold down the arrow key in the FINE mode, “f” is
displayed around the adjustment position.
9
If the CROSS HAIR pattern is off-centered on the screen, adjust the
centering again and repeat steps
1
to
8
for the horizontal scale
adjustment.
For details of the centering adjustment, see “Red CENT (centering)
adjustment” on page 108.
10
Press the LIN key.
a
a
b
b
(continued)
Summary of Contents for VPH-G90E
Page 10: ......
Page 120: ......
Page 122: ...2 2 VPH G90E G90U G90M 2 1 3 Location 3 ME MB MC PB M L MA BA F BC NA BB ...
Page 190: ......
Page 204: ......
Page 210: ......
Page 224: ......
Page 337: ...9 1 9 1 VPH G90E G90U G90M SECTION 9 BLOCK DIAGRAMS ...
Page 363: ...2 3 4 5 A B C D E F G H 1 10 1 10 1 VPH G90J G90E G90U G90M SECTION 10 DIAGRAMS ...
Page 437: ...2 3 4 5 A B C D E F G H 1 10 75 10 75 VPH G90J G90E G90U G90M ...
Page 474: ...2 3 4 5 A B C D E F G H 1 10 112 10 112 VPH G90J G90E G90U G90M ...