59
OUTPUT A
MONITOR output terminal:
Mini D-sub 15-pin
female, G with sync/Y: 1 Vp-p ± 2 dB, sync negative,
75 ohms terminated, RGB/P
B
P
R
: 0.7 Vp-p ± 2 dB,
75 ohms terminated, Sync signal: HD, VD 4 V (open),
1 Vp-p (75 ohms), positive/negative
Audio output terminal:
Stereo mini jack, stereo,
1 Vrms (maximum volume, when inputting 500 mVrms),
output impedance 5 kilohms
OUTPUT B
DVI-D output terminal:
DVI-D 24-pin (Single link),
DVI 1.0 compliant, non-HDCP compliant
Control signal
input/output
RS-232C terminal:
D-Sub 9 pin male
LAN terminal:
RJ45, 10BASE-T/100BASE-TX
CONTROL S input terminal (DC power supply):
Stereo mini jack, 5 Vp-p, Plug in power DC 5 V
Operating
temperature/
Operating
humidity
0 °C to 40 °C (32 °F to 104 °F)/20% to 80% (no
condensation)
Storage
temperature/
Storage humidity
–10 °C to +60 °C (14 °F to +140 °F)/ 20% to 80% (no
condensation)
Power required
VPL-FHZ75:
AC 100 V to 240 V, 5.4 A to 2.2 A,
50/60 Hz
VPL-FHZ70:
AC 100 V to 240 V, 4.9 A to 2.0 A,
50/60 Hz
Power
consumption
AC 100 V to
120 V
VPL-FHZ75:
537 W
VPL-FHZ70:
483 W
AC 220 V to
240 V
VPL-FHZ75:
518 W
VPL-FHZ70:
468 W
Power
consumption
(Standby Mode)
AC 100 V to
120 V
0.50 W (when “Standby Mode” is set to “Low”)
AC 220 V to
240 V
0.50 W (when “Standby Mode” is set to “Low”)
Power
consumption
(Networked
Standby Mode)
AC 100 V to
120 V
16.0 W (LAN), 20.7 W (HDBaseT), 20.7 W
(All Terminals and Networks Connected)
(when “Standby Mode” is set to “Standard”)
AC 220 V to
240 V
13.3 W (LAN), 18.7 W (HDBaseT), 18.7 W
(All Terminals and Networks Connected)
(when “Standby Mode” is set to “Standard”)
Heat dissipation
AC 100 V to
120 V
VPL-FHZ75:
1,833 BTU/h
VPL-FHZ70:
1,648 BTU/h
AC 220 V to
240 V
VPL-FHZ75:
1,768 BTU/h
VPL-FHZ70:
1,597 BTU/h
Outside
dimensions
460 × 175 × 515 mm (18
1
/
8
" × 6
7
/
8
" × 20
9
/
32
") (W/H/
D)
460 × 169 × 515 mm (18
1
/
8
" × 6
21
/
32
" × 20
9
/
32
") (W/H/
D) (without protrusions)
Item
Description