KE-P42M1 (AEP) 2-2
2-2-5. Y signal AD calibration of CCP2 decode
1.
Check “MON_CON_REG_1” = 3.
(TIMING_AUTO_DETECT is Enable)
2.
Input 0 IRE black full field with burst.
3.
Send “READ_PW_INPUT_Y” command from ECS.
4.
Check that the detection value of “PW_INPUT_Y” is
within the standard of following column.
5.
Input 100 IRE white full field with burst.
6.
Send “ADJUST_Y_LEVEL_VIDEO” command from ECS.
The Y_LEVEL_CCP2_04 registration of the video range is
adjusted automatic by this command.
Adjustment value also is copied in the proper NVM area.
7.
Check that the detection value of “PW_INPUT_Y” is within
the standard of following column.
2-2-6. C signal AD calibration of CCP2 decode
1.
Check “MON_CON_REG_1” = 3.
(TIMING_AUTO_DETECT is Enable)
2.
Input 0 IRE black full field with burst.
3.
Send “READ_PW_INPUT_CB” command from ECS.
4.
Check that the detection value of “PW_INPUT_CB” is
within the standard of following column.
5.
Input blue full field with burst.
6.
Send “ADJUST_C_LEVEL_VIDEO” command from ECS.
The C_LEVEL_CCP2_05 registration of the video range is
adjusted automatic by this command.
Adjustment value also is copied in the proper NVM area.
7.
Check that the detection value of “PW_INPUT_CB” is
within standard of following column.
8.
Input red full field with burst.
9.
Send “READ_PW_INPUT_CR” command from ECS.
10. Check that the detection value of “PW_INPUT_CR” is
within standard ofi following column.
2-2-7. Check AD (Component case) calibration
registration items
1.
Select AV4 and input 575i signal.
2.
Set following items.
Item
Standard
PW_INPUT_Y
Less than 304
Item
Standard
PW_INPUT_CB
Less than 304
Item
Standard
PW_INPUT_Y
3888
±
16
Item
Standard
PW_INPUT_CB
3184
±
16
Item
data
PICTURE_MODE
0 (Live)
COLOR
25
DYNA_PICT
0 (Off)
DC_TRAN
0 (Off)
3.
Check that following items is defalt.
2-2-8. Y signal AD calibration of component input
1.
Check “MON_CON_REG_1” = 3.
(TIMING_AUTO_DETECT is Enable)
2.
Input 0 IRE black full field with burst in AV3.
3.
Send “READ_PW_INPUT_Y” command from ECS.
4.
Check that the detection value of “PW_INPUT_Y” is within
the standard of following column.
5.
Input 100 IRE white full field with burst.
6.
Send “ADJUST_Y_LEVEL_VIDEO” command from ECS.
The Y_LEVEL_CCP2_04 registration of the video range is
adjusted automatic by this command.
Adjustment value also is copied in the proper NVM area.
7.
Check that the detection value of “PW_INPUT_Y” is within
the standard of following column.
2-2-9. C signal AD calibration of componet input
1.
Check “MON_CON_REG_1” = 3.
(TIMING_AUTO_DETECT is Enable)
2.
Input 0 IRE black full field with burst.
3.
Send “READ_PW_INPUT_CB” command from ECS.
4.
Check that the detection value of “PW_INPUT_CB” is
within the standard of following column.
5.
Input blue full field with burst.
6.
Send “ADJUST_C_LEVEL_VIDEO” command from ECS.
The C_LEVEL_CCP2_05 registration of the video range is
adjusted automatic by this command.
Adjustment value also is copied in the proper NVM area.
7.
Check that the detection value of “PW_INPUT_CB” is
within standard of following column.
8.
Input red full field with burst.
9.
Send “READ_PW_INPUT_CR” command from ECS.
10. Check that the detection value of “PW_INPUT_CR” is
within standard ofi following column.
Item
Standard
PW_INPUT_Y
Less than 304
Item
Standard
PW_INPUT_Y
3888
±
16
Item
Standard
PW_INPUT_CB
Less than 304
Item
Standard
PW_INPUT_CB
3760
±
16
TARGET_PW_IN_Y
ADJ_Y_DEADBAND
ADJ_Y_LOOPATTEN
TARGET_PW_IN_C
ADJ_C_ DEADBAND
ADJ_C_ LOOPATTEN
AD_ADJ_TIME_OUT
Item
Standard
PW_INPUT_CR
2832
±
320
Item
Standard
PW_INPUT_CR
3200
±
320