F
u
nc
ti
ons
17
Persistent IP Enable
Enable this when the camera uses a static IP address.
Enable: Use a static IP address.
(When this is enabled, DHCP Enable is disabled.)
Disable: Do not use a static IP address.
Persistent IP Address
Specifies the camera’s static IP address.
Persistent IP Subnet Mask
Specifies the camera’s subnet when using a static IP
address.
Heartbeat Mode
Enable or disable the Heartbeat mode.
Enable: When the heartbeat is enabled and
interrupted, video image transfer is stopped and the
network is initialized.
Disable: Heartbeat is ignored.
Streaming Only: When the heartbeat is enabled and
interrupted, video image transfer is stopped.
Heartbeat Timeout
Specifies the time allowed to reach heartbeat.
Setting range: 500 to 10,000 ms
Timestamp Tick Frequency
Indicates the number of timestamp ticks per second.
The value is fixed at 83,333,333 ticks. This value is also
the same as the timestamp frequency.
Control Channel Privilege
This mode specifies the control method.
0: Ungoverned control (No control commands are
accepted from any application.)
1: Exclusive access (One application has total control,
and other applications cannot even read registers.)
2: Control access (One application has control, and
other applications can only read registers.)
Notes
• If the Payload Size is set to a value smaller than the
Packet Size, images will not be output from the
camera. This is not a malfunction.
• Before changing the Payload Size or Packet Size, stop
image output from the camera. Changing either
parameter without first stopping image output will
result in lost of synchronization between the camera
and the host, making normal image display
impossible.
• When using a static IP address, it is recommended that
the IP addresses on both the camera and the host
device satisfy the following conditions.
IP Address:
169.254.A.B (1
≤
A
≤
255, 1
≤
B
≤
254)
Further, be sure to set different IP
addresses on the camera and the host
device.
Subnet Mask: 255.255.0.0
Saving an IP address other than as recommended
above may prevent the camera from connecting
normally when it is turned back on.