Cont
ro
l O
per
at
io
ns
22
Special trigger Control
Gamma Curve Control
GPI Control
Feature Control Registers
Clamp Control (Model XCG-5005E only)
Address
Name
Type
Bit assignment
31-24
23-16
15-8
7-0
A00002F0h
Special Trigger Source
Select
R/W
0
Sets the trigger source to
“hardware” during special trigger
mode
1
Sets the trigger source to
“software” during special trigger
mode
Address
Name
Type
Bit assignment
31-24
23-16
15-8
7-0
A00002F4h
Special Trigger Polarity
R/W
0
Sets the trigger polarity to
“positive” during special trigger
mode
1
Sets the trigger polarity to
“negative” during special trigger
mode
Address
Name
Type
Bit assignment
31-24
23-16
15-8
7-0
A0000300h
Special Trigger Mode
R/W
0
Normal Mode setting
1
Bulk Mode setting
2
Sequential Mode setting
Address
Name
Type
Bit assignment
31-24
23-16
15-8
7-0
A0000304h
Number Of Frames For
Special Trigger Mode
R/W
1 - 16
Number of frames for special
trigger mode
Address
Name
Type
Bit assignment
31-24
23-16
15-8
7-0
A0000310h
Gamma Value
R/W
Gamma curve coefficient setting
A0000314h
Gamma Low Level
R/W
Sets the black level for the
Gamma curve coefficient
Address
Name
Type
Bit assignment
31-24
23-16
15-8
7-0
A0000400h
GPI
R/O
Read the GPI
Address
Name
Type
Bit assignment
31-24
23-16
15-8
7-0
A0002000h
Clamp (L)
R/W
(L)eft black level
A0002004h
Clamp (R)
R/W
(R)ight black level