Functions of the XCL-V500
XCL-X700/V500
■
External Clock Input Function
Previously, the operating speed of a camera was fixed.
This camera can change its operating speed from the
normal speed to half of that.
Notes
• Be aware that the shift of phase occurs in the range of
– 2
×
CLK to 0 (reference: External-CLK) for
Internal-HD signals depending on the timing when
the power is turned on. The amount of the shift is not
always the same and varies within the range
described above every time the power is turned on.
• Be aware that noise is generated when the Internal/
External clock is switched.
By utilizing the external clock input function, clock
jitter is completely eliminated.
All modes are supported for the Camera Mode.
Previous cameras
This camera
External-HD
Internal-CLK
Internal-HD
External-HD
External-CLK
Internal-CLK
Internal-HD