6-14
2-3. Each Self Check Function
Each Self Check function tests the FLD display, LED display, and
key input.
2-3-1. FLD and LED All ON
2-3-1-1. Transition Keys in Self Check Mode
•
←
key on the remote commander
2-3-1-2. Operation and Display
In this mode, all LEDs except STANDBY LED and all segments
of FLD turn ON.
Example of FLD all ON
2-3-2. Main Unit Key Name Display and Key Code Display
2-3-2-1. Transition Keys in Self Check Mode
• Keys on the main unit except keys transited in Self Check Mode
2-3-2-2. Operation and Display
When a key on the main unit is pressed in the Self Check Mode,
the name of that key is displayed on the FLD. Also, the key name
display and the key code display can be switched with the
[DISPLAY]
key on the remote commander. “NOTHING” is dis-
played when nothing is entered. Also, DVD and VCD segments
turn on when a communication error occurred.
FLD display (at input of
H
key on the main unit)
Input
IC404: Pin No. (Signal)
Voltage [V]
Pin
ef
(AD1)
Pin
eg
(O/C)
Pin
eh
(AD2)
Pin
ej
(POWER)
0 – 0.21
PLAY
OPEN/CLOSE
STOP
POWER
0.63 – 0.86
NEXT
–
PAUSE
–
1.23 – 1.55
PREVIOUS
–
–
–
1.9 – 2.25
–
–
–
–
2.63 – 2.86
–
–
–
–