7-2
3. Checking S Video Output S-C
(EXCEPT AEP, UK, RUS)
<Purpose>
This checks whether the S video output S-C satisfies the NTSC/
PAL Standard. If it is not correct, the colors will be too dark or
light.
Mode
Video level adjustment in test mode
Signal
Color bars
Test point
S VIDEO OUT (S-C) connector
(75
Ω
terminated)
Instrument
Oscilloscope
Specification
A = 286
±
30 mVp-p (NTSC)
A = 300
±
100 mVp-p (PAL)
Checking method:
1) In the test mode initial menu “6” Video Level Adjustment, set
so that color bars are generated.
2) Confirm that the S-C burst is “A”.
Figure 7-3
4. Checking Component Video Output Y
(EXCEPT AEP, UK, RUS)
<Purpose>
This checks component video output Y. If it is incorrect, correct
brightness will not be attained when connected to, for instance,
projector.
Mode
Video level adjustment in test mode
Signal
Color bars
Test point
COMPONENT VIDEO OUT (Y)
connector (75
Ω
terminated)
Instrument
Oscilloscope
Specification
1.00
±
0.05 Vp-p
Checking method:
1) In the test mode initial menu “6” Video Level Adjustment, set
so that color bars are generated.
2) Confirm that the Y level is 1.00
±
0.05 Vp-p.
Figure 7-4
7-2. ADJUSTMENT OF VIDEO SYSTEM
1. Video Level Adjustment (MB-108 BOARD)
<Purpose>
This adjustment is made to satisfy the NTSC/PAL standard, and if
not adjusted correctly, the brightness will be too large or small.
Mode
Video level adjustment in test mode
Signal
Color bars
Test point
LINE OUT (VIDEO) connector
(75
Ω
terminated)
Instrument
Oscilloscope
Adjusting element
RV401
Specification
1.00 Vp-p
Adjusting method:
1) In the test mode initial menu “6” Video Level Adjustment, set
so that color bars are generated.
2) Adjust the RV401 to attain 1.00 Vp-p.
Figure 7-1
2. Checking S Video Output S-Y
(EXCEPT AEP, UK, RUS)
<Purpose>
Check S-terminal video output. If it is incorrect, pictures will not
be displayed correctly in spite of connection to the TV with a S-
terminal cable.
Mode
Video level adjustment in test mode
Signal
Color bars
Test point
S VIDEO OUT (S-Y) connector
(75
Ω
terminated)
Instrument
Oscilloscope
Specification
1.00
±
0.05 Vp-p
Checking method:
1) In the test mode initial menu “6” Video Level Adjustment, set
so that color bars are generated.
2) Confirm that the S-Y level is 1.00
±
0.05 Vp-p.
Figure 7-2
+0.04
–0.02
A
+ 0.04
– 0.02
1.00 Vp-p
+0.04
–0.02
1.00
±
0.05 Vp-p
1.00
±
0.05 Vp-p