7-3
5. Checking Component Video Output B-Y
(EXCEPT AEP, UK, RUS)
<Purpose>
This checks component video output B-Y. If it is incorrect, cor-
rect colors will not be displayed when connected to, for instance,
component input projector.
Mode
Video level adjustment in test mode
Signal
Color bars
Test point
COMPONENT VIDEO OUT (P
B
)
connector (75
Ω
terminated)
Instrument
Oscilloscope
Specification
A=700
±
50 mVp-p (others)
A=646
±
50 mVp-p (For CND)
Checking method:
1) In the test mode initial menu “6” Video Level Adjustment, set
so that color bars are generated.
2) Confirm that the B-Y level is A.
Figure 7-5
6. Checking Component Video Output R-Y
(EXCEPT AEP, UK, RUS)
<Purpose>
This checks component video output R-Y. If it is incorrect, cor-
rect colors will not be displayed when connected to, for instance,
component input projector.
Mode
Video level adjustment in test mode
Signal
Color bars
Test point
COMPONENT VIDEO OUT (P
R
)
connector (75
Ω
terminated)
Instrument
Oscilloscope
Specification
A=700
±
50 mVp-p (others)
A=646
±
50 mVp-p (For CND)
Checking method:
1) In the test mode initial menu “6” Video Level Adjustment, set
so that color bars are generated.
2) Confirm that the R-Y level is A.
Figure 7-6
7. Checking RGB Output R (AEP, UK, RUS)
<Purpose>
This checks RGB output R. If it is incorrect, pictures will not be
displayed correctly in spite of connection to the TV with an EURO
AV connecting cord.
Mode
Play
Signal
Check the Color-bar (100%) signal
on DVD reference disc
Test point
LINE (RGB)-TV connector
pin
qg
(75
Ω
terminated)
Instrument
Oscilloscope
Specification
700
±
100 mVp-p
Checking method:
1) Confirm that the R level is 700
±
100 mVp-p.
Figure 7-7
8. Checking RGB Output G (AEP, UK, RUS)
<Purpose>
This checks RGB output G. If it is incorrect, pictures will not be
displayed correctly in spite of connection to the TV with an EURO
AV connecting cord.
Mode
Play
Signal
Check the Color-bar (100%) signal
on DVD reference disc
Test point
LINE (RGB)-TV connector
pin
qa
(75
Ω
terminated)
Instrument
Oscilloscope
Specification
700
±
100 mVp-p
Checking method:
1) Confirm that the G level is 700
±
100 mVp-p.
Figure 7-8
700
±
100 mVp-p
700
±
100 mVp-p
A
A