1-5.
Using Extension Boards
Three types of extension boards are prepared for the XVS-8000 to extend plug-in boards.
Extension board EX-1132B
Part number: A-2117-750-A
Extension board EX-1132B is used when inspecting the following plug-in boards.
• CA-92
• OUT-38/38A
• MIX-57
• VPR-129/129A
• DVP-53A
Extension board EX-1295
Part number: A-2117-748-A
Extension board EX-1295 is used when inspecting the XPT-38 board.
Extension board EX-1296
Part number: A-2117-749-A
Extension board EX-1296 is used when inspecting the following connector boards.
• CNI-43
• CNO-43
• NET-28/28A
CAUTION
Before installing and removing an extension board, be sure to turn off the all power switches and disconnect
the all power cables.
Installing or removing an extension board with power turned on may cause electric shock or damage to
boards.
1-5-1.
Extension Board EX-1132B
Procedure
1.
Remove the front panel. (Refer to
)
2.
Remove the board to be inspected or adjusted.
Note
When a blank panel is attached to the slot of the board to be inspected or adjusted, detach the blank panel.
XVS-8000-C/XVS-8000
1-9