11
XP-ZR810
Connection:
[MAIN BOARD] (Side B)
TP601 (RF)
2 K
Ω
Oscilloscope
(AC range)
SL825(OPEN)
IC302
IC601
IC801
TP601(RF)
SECTION 4
ELECTRICAL ADJUSTMENTS
The CD section adjustments are done automatically in this set.
Precautions for Check
1. Perform check in the order given.
2. Use YEDS-18 disc (Part No.: 3-702-101-01) unless otherwise
indicated.
3. Power supply voltage requirement : DC4.5 V in DC IN jack.
(J401)
VOLUME : Minimum
HOLD switch : OFF
Focus bias Check
Condition:
• Hold the set in horizontal state.
• Terminate SL825 (OPEN) by solder.
Procedure:
1. Connect the oscilloscope to the test point TP601 (RF) on the
MAIN board.
2. Set a disc. (YEDS-18)
3. Press the
u
button.
4. Check the oscilloscope waveform is as shown below.
A good eye pattern means that the diamond shape (
◊
) in the
center of the waveform can be clearly distinguished.
RF Signal reference Waveform (Eye Pattern)
To watch the eye pattern, set the oscilloscope to AC range and
RF level
0.4 to 0.7 Vp-p
VOLT/DIV : 100 mV (With the 10 : 1 probe in use)
TIME/DIV : 500n
s
CD SECTION
increase the vertical sensitivity of the oscilloscope for easy
watching.
5. Stop revolving of the disc motor by pressing the
x
button.