21
XTL-W7000
Operation:
[DSLP]
button : Switch the displays to “ERROR CORD” and
“ERROR TEMP” (temperature when error
occurred (hexadecimal number)).
[BACK]
button : Back to the menu screen.
Error cord:
Error code
Detail of error
00
No error occur
01
Slide open error
02
Angle open error
03
Angle close error
04
Slide close error
05
Slide adjustment error
06
Angle adjustment error
07
Tilt operation error
08
Temperature error
(05h (–40
°
C) or less, FBh (+140
°
C) and over)
09
Time over of open/close operation
(over 30 seconds)
3-3-5. ERROR INIT mode
This mode is used to initialize the error history.
In the MECHA mode menu screen, press the
[5]
button on the remote
commander to start initialize the error history.
3-4. MONITOR1 Mode
Note 1:
This mode is used to adjustment of the IC401 on MONITOR board.
(refer to “Section 4 ELECTRICAL ADJUSTMENTS” for details
of adjustments)
Note 2:
No change input color system (NTSC/PAL) if press the
[BACK]
or
[OFF]
button on the remote commander to data save and releasing
this mode. If color sysem is changed or no signal inputed, fault
data is written.
In the ENGINEER menu screen, press the
[4]
button on the remote
commander to enter the MONITOR1 mode and display as following
figure.
When enter this mode, it set the signal format system to NTSC
mode and selects the “VIDEO2” mode automatically.
All operations in this mode are performed using remote control.
The operation of each button in this mode are as following table.
Button
Function
V
/
v
Select the item
VOL –/+
Change the adjustment value of selected item
DISPLAY
On/off switching of the OSD
BACK
Save the adjusted data, and back to the
ENGINEER menu screen
Factory default value of each items:
Display
Setting Item
Value
BRT
Bright
90
CNT
Contrast
154
COL
Color gain
133
HUE
Hue
125
G1
Gamma 1
117
G2
Gamma 2
80
WPL
White peak limiter
125
BPL
Black limiter
65
COM
V COM AMP
71
VDN
V COM DC (for NTSC)
83
SHP
Sharpness
88
YGA
Y gain
122
VCO
VCO free run
128
CEN
H. CENT
16
VDP
V COM DC (for PAL)
103
3-5. MONITOR2 Mode
Note 1:
This mode is used to adjustment of the IC401 on MONITOR board.
(refer to “Section 4 ELECTRICAL ADJUSTMENTS” for details
of adjustments)
Note 2:
No change input color system (NTSC/PAL) if press the
[BACK]
or
[OFF]
button on the remote commander to data save and releasing
this mode. If color sysem is changed or no signal inputed, fault
data is written.
In the ENGINEER menu screen, press the
[5]
button on the remote
commander to enter the MONITOR2 mode and display as following
figure.
When enter this mode, it set the signal format system to NTSC
mode and selects the “VIDEO2” mode automatically.
All operations in this mode are performed using remote control.
The operation of each button in this mode are as following table.
Button
Function
V
/
v
Select the item
VOL –/+
Change the adjustment value of selected item
DISPLAY
On/off switching of the OSD
BACK
Save the adjusted data, and back to the
ENGINEER menu screen
Factory default value of each items:
Display
Setting Item
Value
VDN
V COM DC (for NTSC)
83
COM
V COM AMP
71
RB
Sub bright red
135
BB
Sub bright blue
140
RC
Sub contrast red
100
BC
Sub contrast blue
180
VDP
V COM DC (for PAL)
103
TEST MONITOR1
BRT*** G1 *** COM*** VCO***
CNT*** G2 *** VDN*** CEN***
COL*** WPL*** SHP*** VDP***
HUE*** BPL*** YGA***
TEST MONITOR2
VDN*** RB *** RC *** VDP***
COM*** BB *** BC***