14
ZS-H10CP/H20CP
SECTION 5
ELECTRICAL ADJUSTMENTS
TUNER SECTION
0 dB=1
µ
V
[AM]
Setting:
Function: RADIO
Band: AM
[FM]
Setting:
Function: RADIO
Band: FM
•
Repeat the procedures in each adjustment several times, and
the tracking adjustments should be finally done by the trimmer
capacitors.
•
Remove FM antenna in FM adjustment.
AM RF signal
generator
30% amplitude
modulation by
400 Hz signal
Output level:
as low as possible
Put the lead-wire
antenna close to
the set.
+
–
level meter
set
32
Ω
JACK Board
i
jack (J302)
FM RF signal
generator
75 kHz frequency
deviation by 1 kHz
signal
Output level:
as low as possible
+
–
level meter
0.01
µ
F
TUNER board
TP (GND)
TUNER board
TP (ANT)
set
32
Ω
JACK Board
i
jack (J302)
digital voltmeter
TP (VT)
TP (GND)
100 k
Ω
TU board
AM IF ADJUSTMENT
Adjust for a maximum reading on level meter
T1
450 kHz
(
): H20CP: E model
AM FREQUENCY COVERAGE ADJUSTMENT
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L4
530 kHz (531 kHz)
1.0
±
0.1 V
Confirmation
1,710 kHz
5.1
±
0.4 V (5.0
±
0.4 V)
(1,611 kHz)
(
): H20CP: E model
AM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L3
620 kHz (621 kHz)
CT3
1,400 kHz (1,404 kHz)
FM IF ADJUSTMENT
Adjust for a minimum reading on level meter
T2
10.7 MHz
FM FREQUENCY COVERAGE ADJUSTMENT
Adjustment Part
Frequency Display
Reading on Digital Voltmeter
L2
108 MHz
3.0
±
0.2 V
Confirmation
87.5 MHz
1.3
±
0.3 V
FM TRACKING ADJUSTMENT
Adjust for a maximum reading on level meter
L1
87.5 MHz
CT1
108 MHz
Adjustment and Connecting Location: TU board
(See page 15)